Cont Rev 18A AC3+220V Coil

R2,662.51

Reversing Contactor, TeSys Deca, 3P(3NO), AC-3, <=440V, 18A, 230V AC 50/60Hz coil, screw clamp terminals

Pay over 3 EQUAL zero-interest instalments of R887.51 with PayJustNow.
Or pay over 12 instalments of with PayJustNow.
Find out how...

Your flexible payment provider.

Example payment for

x 3
0% interest, zero fees.
Pay in 3
x 12
28% interest, plus fees.
Total Payment
Pay in 12

How does PayJustNow work?

You can complete sign-up in under 2 minutes - no need to leave your cart!

3 in stock

Or as low as R532.51 over 5 months interest free, using your credit card. For orders over R1.00.How it works
Category: SKU: LC2D18M7 Brand:

Description

 

Main

RangeTeSys

TeSys Deca

Product nameTeSys D

TeSys Deca

Product or component typeReversing contactor
Device short nameLC2D
Contactor applicationResistive load

Motor control

Utilisation categoryAC-3

AC-1

AC-3e

Device presentationPreassembled with reversing power busbar
Poles description3P
Pole contact composition3 NO
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz

Power circuit: <= 300 V DC

[Ie] rated operational current18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

Motor power kW4 KW at 220…230 V AC 50…60 Hz

7.5 KW at 380…400 V AC 50…60 Hz

9 KW at 415 V AC 50…60 Hz

9 KW at 440 V AC 50…60 Hz

10 KW at 500 V AC 50…60 Hz

10 KW at 660…690 V AC 50…60 Hz

Motor power hp1 Hp at 115 V AC 60 Hz for 1 phase motors

3 Hp at 230/240 V AC 60 Hz for 1 phase motors

5 Hp at 200/208 V AC 60 Hz for 3 phases motors

5 Hp at 230/240 V AC 60 Hz for 3 phases motors

10 Hp at 460/480 V AC 60 Hz for 3 phases motors

15 Hp at 575/600 V AC 60 Hz for 3 phases motors

 Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage230 V AC 50/60 Hz
Auxiliary contact composition1 NO + 1 NC
[Uimp] rated impulse withstand voltage6 KV conforming to IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit

32 A (at 60 °C) for power circuit

Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1

250 A DC for signalling circuit conforming to IEC 60947-5-1

300 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current40 A 40 °C – 10 min for power circuit

84 A 40 °C – 1 min for power circuit

145 A 40 °C – 10 s for power circuit

240 A 40 °C – 1 s for power circuit

100 A – 1 s for signalling circuit

120 A – 500 ms for signalling circuit

140 A – 100 ms for signalling circuit

Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1

50 A gG at <= 690 V coordination type 1 for power circuit

35 A gG at <= 690 V coordination type 2 for power circuit

Average impedance2.5 MOhm – Ith 25 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1

Power circuit: 600 V CSA certified

Power circuit: 600 V UL certified

Signalling circuit: 690 V conforming to IEC 60947-1

Signalling circuit: 600 V CSA certified

Signalling circuit: 600 V UL certified

Electrical durability1.65 Mcycles 18 A AC-3 at Ue <= 440 V

1 Mcycles 32 A AC-1 at Ue <= 440 V

1.65 Mcycles 18 A AC-3e at Ue <= 440 V

Power dissipation per pole0.8 W AC-3

2.5 W AC-1

0.8 W AC-3e

Protective coverWith
Interlocking typeMechanical
Mounting supportPlate

Rail

StandardsCSA C22.2 No 14

EN 60947-4-1

EN 60947-5-1

IEC 60947-4-1

IEC 60947-5-1

UL 508

IEC 60335-1

Product certificationsDNV[RETURN]CSA[RETURN]CCC[RETURN]UL[RETURN]GL[RETURN]LROS (Lloyds register of shipping)[RETURN]BV[RETURN]RINA[RETURN] GOST[RETURN]UKCA
Connections – terminalsPower circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end

Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end

Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end

Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end

Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid

Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid

Tightening torquePower circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriverpozidriv No 2

Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriverpozidriv No 2

Operating time12…22 ms closing

4…19 ms opening

Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability15 Mcycles
Maximum operating rate3600 Cyc/H 60 °C

 

Complementary

Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz

0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz

0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz

1…1.1 Uc (60…70 °C):operational AC 50/60 Hz

Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C)

70 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C)

7 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation2…3 W at 50/60 Hz
Auxiliary contacts typeType mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching current5 MA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non-overlap time1.5 Ms on de-energisation between NC and NO contact

1.5 Ms on energisation between NC and NO contact

Insulation resistance> 10 MOhm for signalling circuit

 

Environment

 

IP degree of protectionIP20 front face conforming to IEC 60529
Climatic withstandConforming to IACS E10

conforming to IEC 60947-1 Annex Q category D

Protective treatmentTH conforming to IEC 60068-2-30
Pollution degree3
Ambient air temperature for operation-40…60 °C

60…70 °C with derating

Ambient air temperature for storage-60…80 °C
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 confirming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)

Vibrations contactor closed (4 Gn, 5…300 Hz)

Shocks contactor open (10 Gn for 11 ms)

Shocks contactor closed (15 Gn for 11 ms)

Height77 Mm
Width90 Mm
Depth86 Mm
Net weight0.707 Kg

 

Packing Units

 

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.300 Cm
Package 1 Width11.500 Cm
Package 1 Length14.000 Cm
Package 1 Weight804.000 Kg
Unit Type of Package 2S02
Number of Units in Package 26
Package 2 Height15.000 Cm
Package 2 Width30.000 Cm
Package 2 Length40.000 Cm
Package 2 Weight5.150 Kg
Unit Type of Package 3P06
Number of Units in Package 396
Package 3 Height75.000 Cm
Package 3 Width60.000 Cm
Package 3 Length80.000 Cm
Package 3 Weight90.400 Kg

 

Additional information

Weight0.48 kg
Dimensions7.4 × 4.5 × 8 cm