Cont Rev 80A AC3+220V Coil

R17,253.66

FloatOr as low as R3,450.74 / month interest-free, using your existing credit card. For orders over R100.00.How it works

Reversing Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V 80A, 230V AC 50/60Hz coil, screw clamp terminals

10 in stock

Categories: , SKU: LC2D80P7

Description

 

Main

Range TeSys

TeSys Deca

Product name TeSys D

TeSys Deca

Product or component type Reversing contactor
Device short name LC2D
Contactor application Motor control

Resistive load

Utilisation category AC-1

AC-3

AC-3e

AC-4

Device presentation Preassembled with reversing power busbar
Poles description 3P
Pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz

Power circuit: <= 300 V DC

[Ie] rated operational current 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

55 A (at <60 °C) at <= 400 V AC AC-4 for power circuit

Motor power kW 22 KW at 220…230 V AC 50 Hz

37 KW at 380…400 V AC 50 Hz

45 KW at 415…440 V AC 50 Hz

55 KW at 500 V AC 50 Hz

45 KW at 660…690 V AC 50 Hz

Motor power hp 20 Hp at 200/208 V AC 60 Hz for 3 phases motors

7.5 Hp at 115 V AC 60 Hz for 1 phase motors

15 Hp at 230/240 V AC 60 Hz for 1 phase motors

25 Hp at 230/240 V AC 60 Hz for 3 phases motors

60 Hp at 460/480 V AC 60 Hz for 3 phases motors

60 Hp at 575/600 V AC 60 Hz for 3 phases motors

 Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 110 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 8 KV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit

125 A (at 60 °C) for power circuit

Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1

250 A DC for signalling circuit conforming to IEC 60947-5-1

1100 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 135 A 40 °C – 10 min for power circuit

320 A 40 °C – 1 min for power circuit

640 A 40 °C – 10 s for power circuit

990 A 40 °C – 1 s for power circuit

100 A – 1 s for signalling circuit

120 A – 500 ms for signalling circuit

140 A – 100 ms for signalling circuit

Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1

200 A gG at <= 690 V coordination type 1 for power circuit

160 A gG at <= 690 V coordination type 2 for power circuit

Average impedance 0.8 MOhm – Ith 25 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V CSA certified

Power circuit: 600 V UL certified

Signalling circuit: 690 V conforming to IEC 60947-1

Signalling circuit: 600 V CSA certified

Signalling circuit: 600 V UL certified

Power circuit: 1000 V conforming to IEC 60947-4-1

Electrical durability 0.8 Mcycles 125 A AC-1 at Ue <= 440 V

1.5 Mcycles 80 A AC-3 at Ue <= 440 V

1.5 Mcycles 80 A AC-3e at Ue <= 440 V

Power dissipation per pole 12.5 W AC-1

5.1 W AC-3

5.1 W AC-3e

Protective cover With
Interlocking type Mechanical
Mounting support Plate

Rail

Standards CSA C22.2 No 14

EN 60947-4-1

EN 60947-5-1

IEC 60947-4-1

IEC 60947-5-1

UL 508

Product certifications DNV[RETURN]CSA[RETURN]CCC[RETURN]UL[RETURN]GL[RETURN]LROS (Lloyds register of shipping)[RETURN]BV[RETURN]RINA[RETURN] GOST[RETURN]UKCA
Connections – terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid

Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end

Power circuit: connector 1 cable(s) 4…50 mm²flexible without cable end

Power circuit: connector 2 cable(s) 4…25 mm²flexible without cable end

Power circuit: connector 1 cable(s) 4…50 mm²flexible with cable end

Power circuit: connector 2 cable(s) 4…16 mm²flexible with cable end

Power circuit: connector 1 cable(s) 4…50 mm²solid

Power circuit: connector 2 cable(s) 4…25 mm²solid

Tightening torque Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2

Power circuit: 12 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm

Power circuit: 12 N.m – on connector hexagonal screw head 4 mm

Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriverpozidriv No 2

Operating time 20…35 ms closing

6…20 ms opening

Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability 4 Mcycles
Maximum operating rate 3600 Cyc/H 60 °C

 

Complementary

Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz

0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz

0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz

1…1.1 Uc (60…70 °C):operational AC 50/60 Hz

Inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 20 °C)

245 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 20 °C)

26 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation 6…10 W at 50/60 Hz
Auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching current 5 MA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 Ms on de-energisation between NC and NO contact

1.5 Ms on energisation between NC and NO contact

Insulation resistance > 10 MOhm for signalling circuit

 

Environment

 

IP degree of protection IP20 front face conforming to IEC 60529
Climatic withstand Conforming to IACS E10

conforming to IEC 60947-1 Annex Q category D

Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -40…60 °C

60…70 °C with derating

Ambient air temperature for storage -60…80 °C
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 confirming to IEC 60695-2-1
Mechanical robustness Vibrations contactor open: 2 Gn, 5…300 Hz

Shocks contactor open: 8 Gn for 11 ms

Vibrations contactor closed: 3 Gn, 5…300 Hz

Shocks contactor closed: 10 Gn for 11 ms

Height 127 Mm
Width 182 Mm
Depth 158 Mm
Net weight 3.2 Kg

 

Packing Units

 

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19 Cm
Package 1 Width 19 Cm
Package 1 Length 25.5 Cm
Package 1 Weight 3.726 Kg
Unit Type of Package 2 S03
Number of Units in Package 2 2
Package 2 Height 30 Cm
Package 2 Width 30 Cm
Package 2 Length 40 Cm
Package 2 Weight 8.165 Kg

 

Additional information

Weight 0.877 kg
Dimensions 2.3 × 1.8 × 2 cm