Description
Commercial data
Item number | 2866310 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | CMP |
Product key | CMPU13 |
Catalog page | Page 266 (C-4-2019) |
GTIN | 4046356729192 |
Weight per piece (incl. packing) | 187,02 g |
Weight per piece (excl. packing) | 147 g |
Customs tariff number | 85044095 |
Country of origin | VN |
UNO-PS/1AC/24DC/ 30W – Power supply unit
Technical data
Input data
AC operation
Parameter | Specification |
Nominal Input Voltage Range | 100 V AC … 240 V AC |
Input Voltage Range | 85 V AC … 264 V AC |
Input Voltage Range AC | 85 V AC … 264 V AC |
Voltage Type of Supply Voltage | AC |
Inrush Current | < 30 A (typ.) |
Inrush Current Integral (I2 t) | < 0.4 A2 s (typ.) |
AC Frequency Range | 50 Hz … 60 Hz |
Frequency range (fN ) | 50 Hz … 60 Hz ±10 % |
Mains Buffering Time | > 25 ms (120 V AC)
> 115 ms (230 V AC) |
Current Consumption | typ. 0.8 A (100 V AC)
typ. 0.4 A (240 V AC) |
Nominal Power Consumption | 72.1 VA |
Protective Circuit | Transient surge protection; Varistor |
Power Factor (cos phi) | 0.47 |
Typical Response Time | < 1 s |
Input Fuse | 2 A (slow-blow, internal) |
Recommended Breaker for Input Protection | 6 A … 16 A (Characteristics B, C, D, K) |
Output data
Efficiency | typ. 87 % (120 V AC)
typ. 88 % (230 V AC) |
Output characteristic | HICCUP |
Nominal output voltage | 24 V DC |
Nominal output current (IN) | 1.25 A (-25 °C … 55 °C) |
Derating | 55 °C … 70 °C (2.5 %/K) |
Feedback voltage resistance | < 35 V DC |
Protection against overvoltage (OVP) | ≤ 35 V DC |
Control deviation | < 1% (change in load, static 10% … 90%)
< 2% (change in load, dynamic 10% … 90%) < 0.1% (change in input voltage ±10%) |
Residual ripple | < 60 mVPP (with nominal values) |
Short-circuit-proof | yes |
Output power | 30 W |
Maximum no-load power dissipation < | 0.3 W |
Power loss nominal load max. | < 5 W |
Rise time | < 0.5 s (UOUT (10 % … 90 %)) |
Response time | < 2 ms |
Connection in parallel | yes, for redundancy and increased capacity |
UNO-PS/1AC/24DC/ 30W – Power supply unit
Connection in series | yes |
Connection data
Input
Connection method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 8 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque, max | 0.6 Nm |
Output
Connection method | Screw connection |
Conductor cross section, rigid min. | 0.5 mm² |
Conductor cross section, rigid max. | 6 mm² |
Conductor cross section flexible min. | 0.5 mm |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section, AWG min | 20 |
Conductor cross section AWG max. | 10 |
Stripping length | 14 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque, max | 0.6 Nm |
UNO-PS/1AC/24DC/ 30W – Power supply unit
Signaling
Types of signaling | LED |
Electrical properties
Number of phases | 1.00 |
Insulation voltage output / PE | 4 kV AC (type test)
3 kV AC (routine test) |
Product properties
Product type | Power supply |
Product family | UNO POWER |
MTBF (IEC 61709, SN 29500) | > 1158000 h (40 °C) |
Insulation characteristics
Protection class | II (in closed control cabinet) |
Degree of pollution | 2 |
Dimensions
Width | 22.5 mm |
Height | 90 mm |
Depth | 84 mm |
Installation dimensions
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 30 mm / 30 mm |
Mounting
Mounting type | DIN rail mounting |
Assembly note | alignable: 0 mm horizontally, 30 mm vertically |
Mounting position | Horizontal DIN rail NS 35, EN 60715 |
With protective coating | No |
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
Housing material | Plastic |
Housing material | Polycarbonate |
Foot latch material POM | (Polyoxymethylene) |
Environmental and real-life conditions
Ambient conditions
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C … 70 °C
(> 55° C derating : 2.5%/K) |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Ambient temperature (start-up type tested) | -40 °C |
Climatic class | 3K22 (in accordance with EN 60721-3-3) |
UNO-PS/1AC/24DC/ 30W – Power supply unit
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2- 27) |
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz … 150 Hz, 2.3g, 90 min |
Standards and regulations
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Standard – Electrical safety | IEC 62368-1 (SELV) |
Standard – Safety extra-low voltage | IEC 62368-1 (SELV) und EN 60204-1 (PELV) |
Standard – Safe isolation | DIN VDE 0100-410 |
Standard – Safety of transformers | EN 61558-2-16 |
Approval – requirement of the semiconductor industry with regard to mains voltage dips | EN 61000-4-11 |
Mains voltage dips
Standard designation | Requirement of the semiconductor industry with regard to mains voltage dips |
Standards/specifications | SEMI F47 – 0706 (180 V AC) |
Approvals
CSA | CAN/CSA-C22.2 No. 60950-1-07
CSA-C22.2 No. 107.1-01 CSA CAN/CSA-C22.2 No. 213 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) |
UL approvals | UL/C-UL listed UL 508
NEC Class 2 as per UL 1310 UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) UL approvals UL/C-UL Recognized UL 60950-1 |
Conformity/Approvals
SIL in accordance with IEC 61508 | 0 |
Performance level according to ISO 13849 | without |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
EMC Requirements for Noise Emission | EN 61000-6-3
EN 61000-6-4 |
EMC Requirements for Noise Immunity | EN 61000-6-1
EN 61000-6-2 |
Electromagnetic Compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
Standards/Regulations | EN 61000-4-2 |
UNO-PS/1AC/24DC/ 30W – Power supply unit
Electrostatic discharge
Contact discharge | 6 kV(Test Level 3) |
Discharge in air | 8 kV (Test Level 3) |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Electromagnetic HF field
Frequency Range | 80 MHz … 1 GHz |
Test Field Strength | 10 V/m (Test Level 3) |
Frequency range | 1 GHz … 6 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Fast transients (burst)
Input | 4 kV (Test Level 4 – asymmetrical) |
Output | 4 kV (Test Level 4 – asymmetrical) |
Comments | Criterion B |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Surge voltage load (surge)
Input | 1 kV (Test Level 2 – symmetrical)
2 kV (Test Level 3 – asymmetrical) |
Output | 0.5 kV (Test Level 1 – symmetrical)
1 kV (Test Level 2- asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Conducted interference
Frequency Range | 0.15 MHz … 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Conducted interference
Input/Output | asymmetrical |
Frequency Range | 0.15 MHz … 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Voltage dips
Standards/regulations | EN 61000-4-11 |
Voltage | 230 V AC |
Frequency | 50 Hz |
Voltage dip | 70 % |
UNO-PS/1AC/24DC/ 30W – Power supply unit
Number of periods | 25 periods |
Additional text | Class 3 |
Comments | Criterion A |
Voltage dip | 40 % |
Number of periods | 10 periods |
Additional text | Class 3 |
Comments | Criterion A |
Voltage dip | 0 % |
Number of periods | 1 period |
Additional text | Class 3 |
Comments | Criterion A |
Emitted interference
Standards/regulations | EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) class B used in industry and residential area / EMC 1 |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) class B used in industry and residential area / EMC 1 |
Criteria
Criterion | A Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself |
UNO-PS/1AC/24DC/ 30W – Power supply unit
Classifications
ECLASS
ECLASS-11.0 | 27040701 |
ECLASS-13.0 | 27040701 |
ECLASS-12.0 | 27040701 |
ETIM
ETIM 9.0 | EC002540 |
UNSPSC
UNSPSC 21.0 | 39121000 |
UNO-PS/1AC/24DC/ 30W – Power supply unit
Environmental product compliance
EU RoHS
Fulfills EU RoHS substance requirements | Yes |
Exemption | 6(c), 7(c)-I |
China RoHS
Environment friendly use period (EFUP) | EFUP-25
An article-related China RoHS declaration table can be found in the download area for the respective article under “Manufacturer declaration”. For all articles with EFUP-E, no China RoHS declaration table issued and required |
EU REACH SVHC
REACH candidate substance (CAS No.) | Lead(CAS: 7439-92-1) |
SCIP | 05b42b3b-0bf7-4e8c-94e6-1ecaf9319514 |
EF3.0 Climate Change
CO2e kg | 3,657 kg CO2e |
UNO-PS/1AC/24DC/ 30W – Power supply unit
Accessories
UNO-DIODE/5-24DC/2X10/1X20 – Redundancy module
Redundancy module, 5 V – 24 V DC, 2 x 10 A, 1 x 20 A.
CBMC E4 24DC/1-4A NO – Electronic circuit breaker
Multi-channel electronic circuit breaker for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.
UNO-PS/1AC/24DC/ 30W – Power supply unit
CBMC E4 24DC/1-10A NO – Electronic circuit breaker
Multi-channel electronic circuit breaker for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.
PLT-SEC-T3-230-FM-UT – Type 3 surge protection device
Type 2/3 surge protection, consisting of protective plug and base element with screw connection. For single-phase power supply network with integrated status indicator and remote signaling. Nominal voltage: 230 V AC/DC
UNO-PS/1AC/24DC/ 30W – Power supply unit
PLT-SEC-T3-24-FM-UT – Type 3 surge protection device
Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage: 24 V AC/DC