SCH Everlink Cont Rev 65A 220V

R9,275.68

Reversing Contactor, TeSys Deca, 3P(3NO), AC-3, <=440V, 65A, 230V AC 50/60Hz coil, screw clamp terminals

Pay in 3 or 12. The Clever Way to Pay.
From over 12 months or 3 interest free payments.
Learn more...

Your flexible payment provider.

Example payment for

x 3
0% interest, zero fees.
Pay in 3
x 12
28.25% interest, plus fees.
Total Payment
Pay in 12

How does PayJustNow work?

  • Shop and choose PayJustNow at checkout.
  • Sign up and get instant approval.
  • Pay in 3 or 12.

You can complete sign-up in under 2 minutes - no need to leave your cart!

Out of stock

Category: SKU: LC2D65AM7 Brand:

Description

 

Main

RangeTeSys

TeSys Deca

Product nameTeSys D

TeSys Deca

Product or component typeReversing contactor
Device short nameLC2D
Contactor applicationMotor control

Resistive load

Utilisation categoryAC-1

AC-3

AC-3e

Device presentationPreassembled with reversing power busbar
Poles description3P
Pole contact composition3 NO
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz

Power circuit: <= 300 V DC

[Ie] rated operational current80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

Motor power kW18.5 KW at 220…230 V AC 50 Hz

30 KW at 380…400 V AC 50 Hz

37 KW at 415…440 V AC 50 Hz

37 KW at 500 V AC 50 Hz

37 KW at 660…690 V AC 50 Hz

Motor power hp40 Hp at 460/480 V AC 60 Hz for 3 phases motors

5 Hp at 115 V AC 60 Hz for 1 phase motors

10 Hp at 230/240 V AC 60 Hz for 1 phase motors

20 Hp at 200/208 V AC 60 Hz for 3 phases motors

20 Hp at 230/240 V AC 60 Hz for 3 phases motors

50 Hp at 575/600 V AC 60 Hz for 3 phases motors

 Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage230 V AC 50/60 Hz
Auxiliary contact composition1 NO + 1 NC
[Uimp] rated impulse withstand voltage6 KV conforming to IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit

80 A (at 60 °C) for power circuit

Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1

250 A DC for signalling circuit conforming to IEC 60947-5-1

1000 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current520 A 40 °C – 10 s for power circuit

900 A 40 °C – 1 s for power circuit

110 A 40 °C – 10 min for power circuit

260 A 40 °C – 1 min for power circuit

100 A – 1 s for signalling circuit

120 A – 500 ms for signalling circuit

140 A – 100 ms for signalling circuit

Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1

125 A gG at <= 690 V coordination type 1 for power circuit

125 A gG at <= 690 V coordination type 2 for power circuit

Average impedance1.5 MOhm – Ith 25 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1

Power circuit: 600 V CSA certified

Power circuit: 600 V UL certified

Signalling circuit: 690 V conforming to IEC 60947-1

Signalling circuit: 600 V CSA certified

Signalling circuit: 600 V UL certified

Electrical durability1.45 Mcycles 65 A AC-3 at Ue <= 440 V

1.4 Mcycles 80 A AC-1 at Ue <= 440 V

1.45 Mcycles 65 A AC-3e at Ue <= 440 V

Power dissipation per pole9.6 W AC-1

6.3 W AC-3

6.3 W AC-3e

Protective coverWith
Interlocking typeMechanical
Mounting supportRail

Plate

StandardsCSA C22.2 No 14

EN 60947-4-1

EN 60947-5-1

IEC 60947-4-1

IEC 60947-5-1

UL 508

IEC 60335-1

Product certificationsDNV[RETURN]CSA[RETURN]CCC[RETURN]UL[RETURN]GL[RETURN]LROS (Lloyds register of shipping)[RETURN]BV[RETURN]RINA[RETURN] GOST[RETURN]UKCA
Connections – terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid

Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible without cable end

Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible without cable end

Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible withcable end

Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible withcable end

Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²solid

Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²solid

Tightening torqueControl circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2

Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm ² hexagonal screw head 4 mm

Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm ² hexagonal screw head 4 mm

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriverpozidriv No 2

Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriverpozidriv No 2

Operating time4…19 ms opening

12…26 ms closing

Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability6 Mcycles
Maximum operating rate3600 Cyc/H 60 °C

 

Complementary

Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz

0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz

0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz

1…1.1 Uc (60…70 °C):operational AC 50/60 Hz

Inrush power in VA140 VA 60 Hz cos phi 0.75 (at 20 °C)

160 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C)

15 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation4…5 W at 50/60 Hz
Auxiliary contacts typeType mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching current5 MA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non-overlap time1.5 Ms on de-energisation between NC and NO contact

1.5 Ms on energisation between NC and NO contact

Insulation resistance> 10 MOhm for signalling circuit

 

Environment

 

IP degree of protectionIP20 front face conforming to IEC 60529
Climatic withstandConforming to IACS E10

conforming to IEC 60947-1 Annex Q category D

Protective treatmentTH conforming to IEC 60068-2-30
Pollution degree3
Ambient air temperature for operation-40…60 °C

60…70 °C with derating

Ambient air temperature for storage-60…80 °C
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 confirming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open: 2 Gn, 5…300 Hz

Vibrations contactor closed: 4 Gn, 5…300 Hz

Shocks contactor open: 10 Gn for 11 ms

Shocks contactor closed: 15 Gn for 11 ms

Height122 Mm
Width119 Mm
Depth120 Mm
Net weight1.89 Kg

 

Packing Units

 

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.000 Cm
Package 1 Width16.500 Cm
Package 1 Length19.500 Cm
Package 1 Weight2.074 Kg
Unit Type of Package 2S03
Number of Units in Package 24
Package 2 Height30.000 Cm
Package 2 Width30.000 Cm
Package 2 Length40.000 Cm
Package 2 Weight8.777 Kg
Unit Type of Package 3P06
Number of Units in Package3 16
Package 3 Height45.000 Cm
Package 3 Width60.000 Cm
Package 3 Length80.000 Cm
Package 3 Weight44.110 Kg

 

Additional information

Weight0.48 kg