SCH Everlink Contactor 50A 220V 3P AC3

R2,533.46

Contactor, TeSys Deca, 3P(3 NO), AC-3/ AC-3e, <=400V, 50A, 230V AC 50/60Hz coil, screw clamp terminals

Pay over 3 EQUAL zero-interest instalments of R844.49 with PayJustNow.
Or pay over 12 instalments of with PayJustNow.
Find out how...

Your flexible payment provider.

Example payment for

x 3
0% interest, zero fees.
Pay in 3
x 12
28% interest, plus fees.
Total Payment
Pay in 12

How does PayJustNow work?

You can complete sign-up in under 2 minutes - no need to leave your cart!

1 in stock

Or as low as R506.70 over 5 months interest free, using your credit card. For orders over R1.00.How it works
Category: SKU: LC1D50AM7 Brand:

Description

 

Main

Range TeSys

TeSys Deca

Range of productTeSys Deca
Product or component type Contactor
Contractor applicationMotor control Resistive load

 

Device short nameLC1D
Utilisation category

 

AC-4

AC-1

AC-3

AC-3e

 

Poles description

 

3P

 

[Ue] rated operational voltage

 

Power circuit: <= 690 V AC 25…400 Hz

Power circuit: <= 300 V DC

 

[Ie] rated operational current

 

50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

 

[Uc] control circuit voltage

 

230 V AC 50/60 Hz

 

 

Complementary

Motor power kW

 

15 KW at 220…230 V AC 50/60 Hz (AC-3)

22 KW at 380…400 V AC 50/60 Hz (AC-3)

30 KW at 500 V AC 50/60 Hz (AC-3) 33 KW at 660…690 V AC 50/60 Hz (AC-3)

25 KW at 415 V AC 50/60 Hz (AC-3) 30 KW at 440 V AC 50/60 Hz (AC-3) 11 KW at 400 V AC 50/60 Hz (AC-4) 15 KW at 220…230 V AC 50/60 Hz (AC-3e)

22 KW at 380…400 V AC 50/60 Hz (AC-3e)

30 KW at 500 V AC 50/60 Hz (AC-3e)

33 KW at 660…690 V AC 50/60 Hz (AC-3e)

25 KW at 415 V AC 50/60 Hz (AC-3e) 30 KW at 440 V AC 50/60 Hz (AC-3e)

 

Motor power hp

 

3 Hp at 115 V AC 50/60 Hz for 1 phase motors

7.5 Hp at 230/240 V AC 50/60 Hz for 1 phase motors

15 Hp at 200/208 V AC 50/60 Hz for 3 phases motors

15 Hp at 230/240 V AC 50/60 Hz for 3 phases motors

40 Hp at 460/480 V AC 50/60 Hz for 3 phases motors

40 Hp at 575/600 V AC 50/60 Hz for 3 phases motors

 

Compatibility code

 

LC1D

 

Pole contact composition

 

3 NO

 

Protective cover

 

With

 

[Ith] conventional free air thermal current

 

10 A (at 60 °C) for signalling circuit

80 A (at 60 °C) for power circuit

Irms rated making capacity

 

140 A AC for signalling circuit conforming to IEC 60947-5-1

250 A DC for signalling circuit conforming to IEC 60947-5-1

900 A at 440 V for power circuit conforming to IEC 60947

 

Rated breaking capacity

 

900 A at 440 V for power circuit conforming to IEC 60947

 

[Icw] rated short-time withstand current

 

400 A 40 °C – 10 s for power circuit 810 A 40 °C – 1 s for power circuit 84 A 40 °C – 10 min for power circuit 208 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit

120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit

 

Associated fuse rating

 

10 A gG for signalling circuit conforming to IEC 60947-5-1

80 A gG at <= 690 V coordination type 1 for power circuit

80 A gG at <= 690 V coordination type 2 for power circuit

 

Average impedance

 

1.5 MOhm – Ith 80 A 50 Hz for power circuit

 

Power dissipation per pole

 

3.7 W AC-3

9.6 W AC-1

3.7 W AC-3e

 

[Ui] rated insulation voltage

 

Power circuit: 600 V CSA certified[RETURN]Power circuit: 600 V UL certified[RE- TURN]Signalling circuit: 690 V conforming to IEC 60947-1[RETURN]Signalling- circuit: 600 V CSA certified[RETURN]Signalling circuit: 600 V UL certified[RE- TURN]Power circuit: 690 V conforming to IEC 60947-4-1

 

Overvoltage category

 

III

 

Pollution degree

 

3

 

[Uimp] rated impulse withstand voltage

 

6 KV conforming to IEC 60947

 

Safety reliability level

 

B10d = 1369863 cycles contactor with nominal load conforming-

to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming- to EN/ISO 13849-1

 

Mechanical durability

 

6 Mcycles

 

Electrical durability

 

1.45 Mcycles 50 A AC-3 at Ue <= 440 V

1.1 Mcycles 80 A AC-1 at Ue <= 440 V

1.45 Mcycles 50 A AC-3e at Ue <= 440 V

 

Control circuit type

 

AC at 50/60 Hz standard

 

Coil technology

 

Without built-in suppressor module

 

Control circuit voltage limits

 

0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz

0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz

0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz

1…1.1 Uc (60…70 °C):operational AC 50/60 Hz

 

Inrush power in VA140 VA 60 Hz cos phi 0.75 (at 20 °C)

160 VA 50 Hz cos phi 0.75 (at 20 °C)

 

Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C)

15 VA 50 Hz cos phi 0.3 (at 20 °C)

 

Heat dissipation4…5 W at 50/60 Hz

 

 

Operating time

 

 

 

4…19 ms opening

12…22 ms closing

 

Maximum operating rate

 

3600 Cyc/H 60 °C

 

Maximum operating rate

 

3600 Cyc/H at 60 °C

 

Connections – terminals

 

Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with- cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- out cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with- out cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without- cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without- cable end

Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible- without cable end

Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible- without cable end

Power circuit: screw clamp terminals 1 1…10 mm² – cable stiffness: flexible with- cable end

Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible with- cable end

Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: solid with- out cable end

Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: solid with- out cable end

 

Tightening torque

 

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2

Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver Philips No 2

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver- pozidriv No 2

Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver- pozidriv No 2

 

Auxiliary contact composition

 

1 NO + 1 NC

 

Auxiliary contacts type

 

Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1

 

Signalling circuit frequency

 

25…400 Hz

 

Minimum switching voltage

 

17 V for signalling circuit

 

Minimum switching current

 

5 MA for signalling circuit

 

Insulation resistance

 

> 10 MOhm for signalling circuit

 

Non-overlap time

 

1.5 Ms on de-energisation between NC and NO contact

1.5 Ms on energisation between NC and NO contact

 

Mounting support

 

Rail

Plate

 

 

 

 

 

Environment

 

Standards

 

CSA C22.2 No 14

EN 60947-4-1

EN 60947-5-1

IEC 60947-4-1

IEC 60947-5-1

UL 508

IEC 60335-1

 

Product certifications

 

GL[RETURN]CSA[RETURN]GOST[RETURN]RINA[RETURN]LROS (Lloyds reg- ister of shipping)[RETURN]UL[RETURN]DNV[RETURN]BV[RETURN]CCC[RE- TURN]CB

 

IP degree of protection

 

IP20 front face conforming to IEC 60529

 

Protective  treatment

 

TH conforming to IEC 60068-2-30

 

Climatic withstand

 

Conforming to IACS E10 exposure to damp heat

conforming to IEC 60947-1 Annex Q category D exposure to damp heat

 

Permissible ambient air temperature around the de- vice

 

-40…60 °C

60…70 °C with derating

 

Operating altitude

 

0…3000 m

 

Fire resistance

 

850 °C conforming to IEC 60695-2-1

 

Flame retardance

 

V1 conforming to UL 94

 

Mechanical robustness

 

Vibrations contactor open (2 Gn, 5…300 Hz)

Vibrations contactor closed (4 Gn, 5…300 Hz)

Shocks contactor closed (15 Gn for 11 ms)

Shocks contactor open (10 Gn for 11 ms)

 

Height

 

122 Mm
Width55 Mm
Depth120 Mm
Net weight0.855 Kg

 

 

 

Packing Units

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.2 Cm
Package 1 Width13.5 Cm
Package 1 Length15.5 Cm
Package 1 Weight918.0 G
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height15.0 Cm
Package 2 Width30.0 Cm
Package 2 Length40.0 Cm
Package 2 Weight9.9 Kg
Unit Type of Package 3P06
Number of Units in Package 3160
Package 3 Height77.0 Cm
Package 3 Width80.0 Cm
Package 3 Length60.0 Cm
Package 3 Weight165.06 Kg

 

Additional information

Weight0.045 kg
Dimensions2.54 × 2.54 × 2.54 cm