Description
Main
Range | TeSys
TeSys Deca |
Range of product | TeSys Deca |
Product or component type | Contactor |
Contractor application | Motor control Resistive load
|
Device short name | LC1D |
Utilisation category
|
AC-4
AC-1 AC-3 AC-3e
|
Poles description
|
3P
|
[Ue] rated operational voltage
|
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
|
[Ie] rated operational current
|
80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
|
[Uc] control circuit voltage
|
110 V AC 50/60 Hz
|
Complementary
Motor power kW
|
11 KW at 400 V AC 50/60 Hz (AC-4) 18.5 KW at 220…230 V AC 50/60 Hz (AC-3) 30 KW at 380…400 V AC 50/60 Hz (AC-3) 37 KW at 500 V AC 50/60 Hz (AC-3) 37 KW at 660…690 V AC 50/60 Hz (AC-3) 18.5 KW at 220…230 V AC 50/60 Hz (AC-3e) 30 KW at 380…400 V AC 50/60 Hz (AC-3e) 37 KW at 500 V AC 50/60 Hz (AC-3e) 37 KW at 660…690 V AC 50/60 Hz (AC-3e)
|
Motor power hp
|
40 Hp at 460/480 V AC 50/60 Hz for 3 phases motors
5 Hp at 115 V AC 50/60 Hz for 1 phase motors 10 Hp at 230/240 V AC 50/60 Hz for 1 phase motors 20 Hp at 200/208 V AC 50/60 Hz for 3 phases motors 20 Hp at 230/240 V AC 50/60 Hz for 3 phases motors 50 Hp at 575/600 V AC 50/60 Hz for 3 phases motors
|
Compatibility code
|
LC1D
|
Pole contact composition
|
3 NO
|
Protective cover
|
With
|
[Ith] conventional free air thermal current
|
10 A (at 60 °C) for signalling circuit
80 A (at 60 °C) for power circuit |
Irms rated making capacity
|
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947
|
Rated breaking capacity
|
1000 A at 440 V for power circuit conforming to IEC 60947
|
[Icw] rated short-time withstand current
|
640 A 40 °C – 10 s for power circuit 900 A 40 °C – 1 s for power circuit 110 A 40 °C – 10 min for power circuit 260 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit
|
Associated fuse rating
|
10 A gG for signalling circuit conforming to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit
|
Average impedance
|
1.5 MOhm – Ith 80 A 50 Hz for power circuit
|
Power dissipation per pole
|
9.6 W AC-1
6.3 W AC-3 6.3 W AC-3e
|
[Ui] rated insulation voltage
|
Power circuit: 600 V CSA certified[RETURN]Power circuit: 600 V UL certified[RE- TURN]Signalling circuit: 690 V conforming to IEC 60947-1[RETURN]Signalling- circuit: 600 V CSA certified[RETURN]Signalling circuit: 600 V UL certified[RE- TURN]Power circuit: 690 V conforming to IEC 60947-4-1
|
Overvoltage category
|
III
|
Pollution degree
|
3
|
[Uimp] rated impulse withstand voltage
|
6 KV conforming to IEC 60947
|
Safety reliability level
|
B10d = 1369863 cycles contactor with nominal load conforming-
to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming- to EN/ISO 13849-1
|
Mechanical durability
|
6 Mcycles
|
Electrical durability
|
1.4 Mcycles 80 A AC-1 at Ue <= 440 V
1.45 Mcycles 65 A AC-3 at Ue <= 440 V 1.45 Mcycles 65 A AC-3e at Ue <= 440 V
|
Control circuit type
|
AC at 50/60 Hz standard
|
Coil technology
|
Without built-in suppressor module
|
Control circuit voltage limits
|
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz 1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
|
Inrush power in VA | 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
|
Hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
|
Heat dissipation | 4…5 W at 50/60 Hz
|
Operating time
|
4…19 ms opening 12…22 ms closing
|
Maximum operating rate
|
3600 Cyc/H 60 °C
|
Maximum operating rate
|
3600 Cyc/H at 60 °C
|
Connections – terminals
|
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with- cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- out cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with- out cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without- cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without- cable end Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible- without cable end Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible- without cable end Power circuit: screw clamp terminals 1 1…10 mm² – cable stiffness: flexible with- cable end Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible with- cable end Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: solid with- out cable end Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: solid with- out cable end
|
Tightening torque
|
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver Philips No 2 Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver- pozidriv No 2 Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver- pozidriv No 2
|
Auxiliary contact composition
|
1 NO + 1 NC
|
Auxiliary contacts type
|
Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
|
Signalling circuit frequency
|
25…400 Hz
|
Minimum switching voltage
|
17 V for signalling circuit
|
Minimum switching current
|
5 MA for signalling circuit
|
Insulation resistance
|
> 10 MOhm for signalling circuit
|
Non-overlap time
|
1.5 Ms on de-energisation between NC and NO contact
1.5 Ms on energisation between NC and NO contact
|
Mounting support
|
Rail
Plate
|
Environment |
Standards
|
CSA C22.2 No 14
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1
|
Product certifications
|
GL[RETURN]CSA[RETURN]GOST[RETURN]RINA[RETURN]LROS (Lloyds reg- ister of shipping)[RETURN]UL[RETURN]DNV[RETURN]BV[RETURN]CCC[RE- TURN]CB
|
IP degree of protection
|
IP20 front face conforming to IEC 60529
|
Protective treatment
|
TH conforming to IEC 60068-2-30
|
Climatic withstand
|
Conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
|
Permissible ambient air temperature around the de- vice
|
-40…60 °C
60…70 °C with derating
|
Operating altitude
|
0…3000 m
|
Fire resistance
|
850 °C conforming to IEC 60695-2-1
|
Flame retardance
|
V1 conforming to UL 94
|
Mechanical robustness
|
Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (10 Gn for 11 ms)
|
Height
|
122 Mm |
Width | 55 Mm |
Depth | 120 Mm |
Net weight | 0.86 Kg |
Packing Units
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 1.100 Cm |
Package 1 Width | 1.100 Cm |
Package 1 Length | 1.100 Cm |
Package 1 Weight | 1.100 Kg |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 10 |
Package 2 Height | 15 Cm |
Package 2 Width | 30 Cm |
Package 2 Length | 40 Cm |
Package 2 Weight | 10.3 Kg |