TVS Contactor 25A 240V 11KW 1N/O AC3

R438.67

FloatOr as low as R87.74 / month interest-free, using your existing credit card. For orders over R100.00.How it works

Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,25A,240V AC coil,50Hz,1NO auxiliary contact

3 in stock

Categories: , SKU: LC1E2510U5

Description

 

Main

Range Easy TeSys
Range of product Easy TeSys Control
Product or component type Contactor
Device short name LC1E
Contactor application Motor control

Resistive load

Utilisation category AC-3

AC-1

Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current 25 A (at <55 °C) at <= 440 V AC AC-3 for power circuit

36 A (at <55 °C) at <= 440 V AC AC-1 for power circuit

[Uc] control circuit voltage 240 V AC 50 Hz

 

Complementary

Motor power kW 5.5 KW at 220…230 V AC 50/60 Hz (AC-3)

11 KW at 380…400 V AC 50/60 Hz (AC-3)

11 KW at 415 V AC 50/60 Hz (AC-3)

11 KW at 440 V AC 50/60 Hz (AC-3)

15 KW at 500 V AC 50/60 Hz (AC-3)

15 KW at 660…690 V AC 50/60 Hz (AC-3)

Pole contact composition 3 NO
[Ith] conventional free air thermal current 320 A (at 40 °C)
Irms rated making capacity 250 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity 200 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 240 A 40 °C – 10 s for power circuit

120 A 40 °C – 60 s for power circuit

50 A 40 °C – 600 s for power circuit

Associated fuse rating 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1

40 A gG at <= 690 V coordination type 1 for power circuit

Average impedance 2.5 MOhm – Ith 110 A 50 Hz for power circuit
Power dissipation per pole 1.6 W AC-3

3.2 W AC-1

[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 KV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability 10000000 Cycles
Electrical durability 1200000 Cycles AC-3

350000 Cycles AC-1

Control circuit type AC at 50 Hz
Control circuit voltage limits 0.85…1.1 Uc (-5…55 °C):operational 50 Hz

0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz

Inrush power in VA 95 VA 50 Hz cos phi 0.75 (at 20 °C)

95 VA 60 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA 8.3 VA 60 Hz cos phi 0.3 (at 20 °C)

8.5 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation 2…3 W for control circuit
Operating time 12…22 ms on closing

4…19 ms on opening

Maximum operating rate 1800 Cyc/H 60 °C
Connections – terminals Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end

Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end

Tightening torque Control circuit: 1.2 N.m

Power circuit: 1.5 N.m

Auxiliary contact composition 1 NO
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 MA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 Ms on energisation guaranteed between NC and NO contact

1.5 Ms on de-energisation guaranteed between NC and NO contact

Mounting support Plate

DIN rail

 

Environment

 

Standards IEC 60947-1

IEC 60947-4-1

IEC 60947-5-1

Product certifications ECA [RETURN]CE
IP degree of protection IP2X conforming to IEC 60529
Protective treatment TH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device -20…70 °C at Uc

-60…80 °C storage

-5…55 °C operation

Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Mechanical robustness Vibrations contactor open (1.5 Gn, 5…300 Hz)

Vibrations contactor closed (3 Gn, 5…300 Hz)

Shocks contactor closed (10 Gn for 11 ms)

Shocks contactor open (6 Gn for 11 ms)

Height 74 Mm
Width 45 Mm
Depth 85 Mm
Net weight 0.36 Kg

 

Packing Units

 

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.000 Cm
Package 1 Width 7.500 Cm
Package 1 Length 8.500 Cm
Package 1 Weight 355.000 Kg
Unit Type of Package 2 S02
Number of Units in Package 2 36
Package 2 Height 15.000 Cm
Package 2 Width 30.000 Cm
Package 2 Length 40.000 Cm
Package 2 Weight 13.312 Kg

 

Additional information

Weight 0.48 kg
Dimensions 7.4 × 4.5 × 8 cm