Description
Main
Range | Easy TeSys |
Range of product | Easy TeSys Control |
Product or component type | Contactor |
Device short name | LC1E |
Contactor application | Motor control
Resistive load |
Utilisation category | AC-3
AC-1 |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
[Ie] rated operational current | 9 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
25 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 415 V AC 50 Hz |
Complementary
Motor power kW | 2.2 KW at 220…230 V AC 50/60 Hz (AC-3)
4 KW at 380…400 V AC 50/60 Hz (AC-3) 4 KW at 415 V AC 50/60 Hz (AC-3) 4 KW at 440 V AC 50/60 Hz (AC-3) 5.5 KW at 500 V AC 50/60 Hz (AC-3) 5.5 KW at 660…690 V AC 50/60 Hz (AC-3) |
Pole contact composition | 3 NO |
[Ith] conventional free air thermal current | 25 A (at 55 °C) |
Irms rated making capacity | 90 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 72 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 105 A 40 °C – 10 s for power circuit
61 A 40 °C – 60 s for power circuit 30 A 40 °C – 600 s for power circuit |
Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
20 A gG at <= 690 V coordination type 1 for power circuit |
Average impedance | 2.5 MOhm – Ith 110 A 50 Hz for power circuit |
Power dissipation per pole | 0.2 W AC-3
1.6 W AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 6 KV coil not connected to the power circuit conforming to IEC 60947 |
Mechanical durability | 10000000 Cycles |
Electrical durability | 1400000 Cycles AC-3
150000 Cycles AC-1 |
Control circuit type | AC at 50 Hz |
Control circuit voltage limits | 0.85…1.1 Uc (-5…55 °C):operational 50 Hz
0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz |
Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C)
95 VA 60 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA | 8.3 VA 60 Hz cos phi 0.3 (at 20 °C)
8.5 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 2…3 W for control circuit |
Operating time | 12…22 ms on closing
4…19 ms on opening |
Maximum operating rate | 1800 Cyc/H 60 °C |
Connections – terminals | Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end |
Tightening torque | Control circuit: 1.2 N.m
Power circuit: 1.2 N.m |
Auxiliary contact composition | 1 NO |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 MA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 Ms on energisation guaranteed between NC and NO contact
1.5 Ms on de-energisation guaranteed between NC and NO contact |
Mounting support | Plate
DIN rail |
Environment |
Standards | IEC 60947-1
IEC 60947-5-1 IEC 60947-4-1 |
Product certifications | CE [RETURN]ECA |
IP degree of protection | IP2X conforming to IEC 60529 |
Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db |
Permissible ambient air temperature around the device | -20…70 °C at Uc
-60…80 °C storage -5…55 °C operation |
Operating altitude | 3000 m without derating |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Mechanical robustness | Vibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms) |
Height | 74 Mm |
Width | 45 Mm |
Depth | 80 Mm |
Net weight | 0.3 Kg |
Packing Units
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 5.000 Cm |
Package 1 Width | 7.600 Cm |
Package 1 Length | 8.800 Cm |
Package 1 Weight | 350.000 Kg |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 36 |
Package 2 Height | 15.000 Cm |
Package 2 Width | 30.000 Cm |
Package 2 Length | 40.000 Cm |
Package 2 Weight | 13.120 Kg |