Phoenix Power Supply 2.5Amp Trio 240AC

R1,630.98

TRIO-PS/1AC/24DC/ 2.5 – Power supply unit

 

Primary-switched TRIO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/2.5 A

Pay over 3 EQUAL zero-interest instalments of R543.66 with PayJustNow.
Or pay over 12 instalments of with PayJustNow.
Find out how...

Your flexible payment provider.

Example payment for

x 3
0% interest, zero fees.
Pay in 3
x 12
28% interest, plus fees.
Total Payment
Pay in 12

How does PayJustNow work?

You can complete sign-up in under 2 minutes - no need to leave your cart!

1 in stock

Or as low as R326.20 over 5 months interest free, using your credit card. For orders over R1.00.How it works
Categories: , SKU: PS1002.5 Brand:

Description

Commercial data

Item number2866268
Packing unit1 pc
Minimum order quantity1 pc
Sales key090
Product keyCMPT13
Catalog pagePage 174 (C-6-2013)
GTIN4046356046626
Weight per piece (incl. packing)623.5 g
Weight per piece (excl. packing)500 g
Customs tariff number85044095
Country of originCN

 

TRIO-PS/1AC/24DC/ 2.5 – Power supply unit

2866268 | My ID: PS1002.5

 

Technical data

Input data

AC operation

ParameterSpecification
Nominal Input Voltage Range100 V AC … 240 V AC
Input Voltage Range85 V AC … 264 V AC (Derating < 90 V AC: 2.5 %/V)
Derating< 90 V AC: 2.5 %/V
Electric StrengthMax. 300 V AC
Voltage Type of Supply VoltageAC
Inrush Current< 15 A
Inrush Current Integral (I2 t)0.5 A2s
AC Frequency Range45 Hz … 65 Hz
Mains Buffering Time> 20 ms (120 V AC)

> 100 ms (230 V AC)

Current Consumption0.95 A (120 V AC)

0.5 A (230 V AC)

  
Nominal Power Consumption97 VA
Protective CircuitTransient surge protection; Varistor
Power Factor (cos phi)0.72
Typical Response Time< 1 s
Input Fuse2 A (slow-blow, internal)
Permissible Backup FuseB6 B10 B16
Recommended Breaker for Input Protection6 A … 16 A (Characteristics B, C, D, K)
Discharge Current to PE< 3.5 mA

 

Output data

Efficiency86% (for 230 V AC and nominal values)
Output characteristicU/I
Nominal output voltage24 V DC ±1%
Setting range of output voltage (USet)22.5 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IOUT)2.5 A (UOUT = 24 V DC)
Derating55 °C … 70 °C (2.5%/K)
Feedback voltage resistance35 V DC
Protection against overvoltage (OVP)< 35 V DC
Max. capacitive loadUnlimited
Active current limitationApprox. 5 A (for short-circuit)
Control deviation< 1% (change in load, static 10% … 90%)

< 2% (change in load, dynamic 10% … 90%)

< 0.1% (change in input voltage ±10%)

Residual ripple< 30 mVPP
Output power60 W
Peak switching voltages nominal load< 20 mVPP

 

TRIO-PS/1AC/24DC/ 2.5 – Power supply unit

 

 

Maximum No-load Power Dissipation0.8 W
Power Loss at Nominal Load (Max.)10 W
Rise Time< 2 ms (UOUT 10% to 90%)
Connection in ParallelYes, for redundancy and increased capacity
Connection in SeriesYes

 

Connection data

 

Input

Connection methodScrew connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length9 mm
Screw threadM2.5
Tightening torque, min0.4 Nm
Tightening torque, max0.5 Nm

 

 

 

 

 

Output

Connection methodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section, AWG min24
Conductor cross section AWG min.14
Stripping length9 mm
Screw threadM2.5
Tightening torque, min0.4 Nm
Tightening torque, max0.5 Nm

 

 

Signaling

Types of signalingLED
Operating voltage displayGreen LED

 

Signal output

Status display“DC OK” LED green
Note on status display UOUT > 21.5 V: LED lights up

 

Electrical properties

Insulation voltage input/output4 kV AC (type test)

2 kV AC (routine test)

Insulation voltage output / PE500 V DC (type test)

 

 

 

TRIO-PS/1AC/24DC/ 2.5 – Power supply unit

 

 

Insulation voltage input / PE2 kV AC (type test)

2 kV AC (routine test)

 

Product properties

 

Product typePower supply
Product familyTRIO POWER
MTBF (IEC 61709, SN 29500)> 2054000 h

 

Insulation characteristics

 

Protection classI (with PE connection)
Overvoltage categoryIII
Degree of pollution2

 

Dimensions

Dimensional drawing
Width32 mm
Height130 mm
Depth115 mm

 

Installation dimensions

Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm

Mounting

 

Mounting typeDIN rail mounting
Assembly noteAlignable: horizontally 0 mm, vertically 50 mm
Mounting positionHorizontal DIN rail NS 35, EN 60715
With protective coatingNo

 

Material specifications

 

Housing materialMetal
Type of housingSteel sheet, zinc-plated
Side element versionAluminum

 

Environmental and real-life conditions

Ambient conditions

 

Degree of protectionIP20
Ambient temperature (operation)-25 °C … 70 °C

(> 55° C derating : 2.5%/K)

Ambient temperature (storage/transport)-40 °C … 85 °C
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity≤ 95 % (at 25 °C, non-condensing)

 

TRIO-PS/1AC/24DC/ 2.5 – Power supply unit

 

Shock15g in all directions in acc. with IEC 60068-2-27
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)

15 Hz … 150 Hz, 2.3g, 90 min

 

 

 

Standards and regulations

 

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard – Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Safety extra-low voltageEN 60950-1 (SELV)

EN 60204 (PELV)

Standard – Safe isolationDIN VDE 0100-410

 

 

Approvals

Shipbuilding approvalDNV GL (EMC A)
UL/C-UL listedUL 508
UL/C-UL RecognizedUL 60950-1

 

 

Conformity/Approvals

 

SIL in accordance with IEC 615080

 

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC Requirements for Noise EmissionEN 61000-6-3

EN 61000-6-4

EMC Requirements for Noise ImmunityEN 61000-6-1

EN 61000-6-2

Electromagnetic CompatibilityConformance with EMC Directive 2014/30/EU

 

Electrostatic discharge

Standards/RegulationsEN 61000-4-2

Electrostatic discharge

 

Contact discharge8 kV (Test Level 4)
Discharge in air8 kV (Test Level 3)
CommentsCriterion A

 

Electromagnetic HF field

 

Standards/regulationsEN 61000-4-3

 

Electromagnetic HF field

 

Frequency Range80 MHz … 1 GHz
Test Field Strength10 V/m
Frequency Range1 GHz … 2 GHz
Test Field Strength10 V/m

 

TRIO-PS/1AC/24DC/ 2.5 – Power supply unit

 

Frequency Range2 GHz … 3 GHz
Test Field Strength10 V/m
CommentsCriterion A

 

Fast transients (burst)

 

Standards/regulationsEN 61000-4-4

 

Fast transients (burst)

Input4 kV (Test Level 4 – asymmetrical)
Output2 kV (Test Level 3 – asymmetrical)
CommentsCriterion A

 

Surge voltage load (surge)

 

Standards/regulationsEN 61000-4-5

 

Surge voltage load (surge)

 

Input1 kV (Test Level 2 – symmetrical)

2 kV (Test Level 3 – asymmetrical)

Output0.5 kV (Test Level 1 – symmetrical)

0.5 kV (Test Level 1 – asymmetrical)

CommentsCriterion B

 

Conducted interference

 

Standards/regulationsEN 61000-4-6

 

Conducted interference

 

Frequency Range10 kHz to 15 kHz

10 kHz to 15 kHz

CommentsCriterion A

Criterion A

Voltage3 V (Test Level 2)

3 V (Test Level 2)

 

Conducted interference

 

Frequency Range10 kHz to 15 kHz

10 kHz to 15 kHz

CommentsCriterion A

Criterion A

Voltage3 V (Test Level 2)

3 V (Test Level 2)

 

Voltage dips

 

Standards/regulations EN 61000-4-11

 

Emitted interference

 

Standards/regulations EN 61000-6-3
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential

 

TRIO-PS/1AC/24DC/ 2.5 – Power supply unit

 

Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential

Additional information

Weight1.5 kg
Dimensions11.5 × 3.2 × 13 cm