TVS Contactor 9A 415V 4KW 1N/O AC3

R179.35

Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,9A,415V AC coil,50Hz,1NO auxiliary contact

Open Fact Sheet

Pay over 3 EQUAL zero-interest instalments of R59.79 with PayJustNow.
Or pay over 12 instalments of with PayJustNow.
Find out how...

Your flexible payment provider.

Example payment for

x 3
0% interest, zero fees.
Pay in 3
x 12
28% interest, plus fees.
Total Payment
Pay in 12

How does PayJustNow work?

You can complete sign-up in under 2 minutes - no need to leave your cart!

1 in stock

Or as low as R35.87 over 5 months interest free, using your credit card. For orders over R1.00.How it works
Category: SKU: LC1E0910N5 Brand:

Description

 

Main

RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control

Resistive load

Utilisation categoryAC-3

AC-1

Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current9 A (at <55 °C) at <= 440 V AC AC-3 for power circuit

25 A (at <55 °C) at <= 440 V AC AC-1 for power circuit

[Uc] control circuit voltage415 V AC 50 Hz

 

Complementary

Motor power kW2.2 KW at 220…230 V AC 50/60 Hz (AC-3)

4 KW at 380…400 V AC 50/60 Hz (AC-3)

4 KW at 415 V AC 50/60 Hz (AC-3)

4 KW at 440 V AC 50/60 Hz (AC-3)

5.5 KW at 500 V AC 50/60 Hz (AC-3)

5.5 KW at 660…690 V AC 50/60 Hz (AC-3)

Pole contact composition3 NO
[Ith] conventional free air thermal current25 A (at 55 °C)
Irms rated making capacity90 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity72 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current105 A 40 °C – 10 s for power circuit

61 A 40 °C – 60 s for power circuit

30 A 40 °C – 600 s for power circuit

Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1

20 A gG at <= 690 V coordination type 1 for power circuit

Average impedance2.5 MOhm – Ith 110 A 50 Hz for power circuit
Power dissipation per pole0.2 W AC-3

1.6 W AC-1

[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 KV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability10000000 Cycles
Electrical durability1400000 Cycles AC-3

150000 Cycles AC-1

Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85…1.1 Uc (-5…55 °C):operational 50 Hz

0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz

Inrush power in VA95 VA 50 Hz cos phi 0.75 (at 20 °C)

95 VA 60 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA8.3 VA 60 Hz cos phi 0.3 (at 20 °C)

8.5 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation2…3 W for control circuit
Operating time12…22 ms on closing

4…19 ms on opening

Maximum operating rate1800 Cyc/H 60 °C
Connections – terminalsPower circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end

Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end

Tightening torqueControl circuit: 1.2 N.m

Power circuit: 1.2 N.m

Auxiliary contact composition1 NO
Minimum switching voltage17 V for control circuit
Minimum switching current5 MA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 Ms on energisation guaranteed between NC and NO contact

1.5 Ms on de-energisation guaranteed between NC and NO contact

Mounting supportPlate

DIN rail

 

Environment

 

StandardsIEC 60947-1

IEC 60947-5-1

IEC 60947-4-1

Product certificationsCE [RETURN]ECA
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device-20…70 °C at Uc

-60…80 °C storage

-5…55 °C operation

Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5…300 Hz)

Vibrations contactor closed (3 Gn, 5…300 Hz)

Shocks contactor open (6 Gn for 11 ms)

Shocks contactor closed (7 Gn for 11 ms)

Height74 Mm
Width45 Mm
Depth80 Mm
Net weight0.3 Kg

 

Packing Units

 

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 Cm
Package 1 Width7.600 Cm
Package 1 Length8.800 Cm
Package 1 Weight350.000 Kg
Unit Type of Package 2S02
Number of Units in Package 236
Package 2 Height15.000 Cm
Package 2 Width30.000 Cm
Package 2 Length40.000 Cm
Package 2 Weight13.120 Kg

 