ATS22 SOFT STARTER 3PHASE 140A 230V-440V 75KW

R30,854.11

soft starter-ATS22-control 220Vpower 230V(37kW)/
400-440V(75kW)

Pay over 3 EQUAL zero-interest instalments of R10,284.71 with PayJustNow.
Find out how...

HOW IT WORKS

PayJustNow allows you to pay for your purchase over 3 payments with 0% interest and no fees. Pay a third at checkout and receive your goods immediately. The remaining two instalments are debited on your selected instalment dates.

Browse online or in-store and proceed to checkout

Choose PayJustNow as your payment method

Create your account and receive an instant approval decision

Complete your transaction

WHAT YOU WILL NEED

Be over 18 years old

Be a South African resident

Have a debit or credit card

Have a valid email address

0% INTEREST. 3 PAYMENTS. NO STRESS.

WHY PAY ANY OTHER WAY?

1 in stock

Or as low as R6,170.83 over 5 months interest free, using your credit card. For orders over R0.01.How it works
Categories: , SKU: ATS22C14Q Brand:

Description

Main
Range of product Altistart 22
Product or component type Soft starter
Product destination Asynchronous motors
Product specific application Pumps and fans
Component name ATS22
Network number of phases 3 phases
[Us] rated supply voltage 230…440 V – 15…10 %
Motor power kW 37 kW 230 V
75 kW 400 V
75 kW 440 V
Factory setting current 131 A
Power dissipation in W 82 W for standard applications
Utilisation category AC-53A
Type of start Start with torque control (current limited to 3.5 In)
IcL starter rating 140 A for connection in the motor supply line for standard applications
IP degree of protection IP00

Complementary
Assembly style With heat sink
Function available Internal bypass
Supply voltage limits 195…484 V
Supply frequency 50…60 Hz – 10…10 %
Network frequency 45…66 Hz
Device connection In the motor supply line
To the motor delta terminals
[Uc] control circuit voltage 230 V – 15…10 % 50/60 Hz
Control circuit consumption 20 W
Discrete output number 2
Discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/
O
Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/
O
Minimum switching current 100 mA at 12 V DC (relay outputs)

Maximum switching current 5 A 250 V AC resistive 1 relay outputs
5 A 30 V DC resistive 1 relay outputs
2 A 250 V AC inductive 0.4 20 ms relay outputs
2 A 30 V DC inductive 7 ms relay outputs
Discrete input number 3
Discrete input type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
Discrete input voltage 24 V <= 30 V
Discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
Output current 0.4…1 Icl adjustable
PTC probe input 750 Ohm
communication port protocol Modbus
Connector type 1 RJ45
Communication data link Serial
Physical interface RS485 multidrop
Transmission rate 4800, 9600 or 19200 bps
Installed device 31
Protection type Phase failure: line
Thermal protection: motor
Thermal protection: starter
Marking CE
type of cooling Forced convection
Operating position Vertical +/- 10 degree
Height 356 mm
Width 150 mm
Depth 229.5 mm
Net weight 18 kg
Motor power range AC-3 30…50 kW at 200…240 V 3 phases
55…100 kW at 380…440 V 3 phases
Motor starter type Soft starte

Environment
Electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Standards IEC 60947-4-2
Product certifications UL
CSA
C-Tick
GOST
CCC
Vibration resistance 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
1.5 mm (f= 2…13 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Noise level 56 dB
Pollution degree Level 2 conforming to IEC 60664-1
Relative humidity 0…95 % without condensation or dripping water conforming to IEC 60068-2-3

Ambient air temperature for
operation
-10…40 °C (without derating)
40…60 °C (with current derating 2.2 % per °C)
Ambient air temperature for
storage
-25…70 °C
Operating altitude <= 1000 m without derating
> 1000…< 2000 m with current derating of 2.2 % per additional 100 m