COMPACT CB NX100F 18KA 2P 100A TMD TRIP

R2,623.14

Circuit breaker ComPacT NSX100F AC/DC. 18kA at 415VAC. TMD trip unit 100A. 2 poles 2d

Pay over 3 EQUAL zero-interest instalments of R874.38 with PayJustNow.
Or pay over 12 instalments of with PayJustNow.
Find out how...

Your flexible payment provider.

Example payment for

x 3
0% interest, zero fees.
Pay in 3
x 12
28% interest, plus fees.
Total Payment
Pay in 12

How does PayJustNow work?

You can complete sign-up in under 2 minutes - no need to leave your cart!

1 in stock

Or as low as R524.63 over 5 months interest free, using your credit card. For orders over R1.00.How it works
Categories: , SKU: C10F2TM100 Brand:

Description

Main
Range ComPacT
Product name ComPacT NSX
Device short name NSX100F
Product or component type Circuit breaker
Device application Distribution
Poles description 2P
Protected poles description 2D
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
500 V DC
Network type AC
DC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
Breaking capacity 36 KA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
18 KA Icu at 380/415 V AC 50/60 Hz 1P conforming to IEC 60947-2
15 KA Icu at 440 V AC 50/60 Hz 1P conforming to IEC 60947-2
10 KA Icu at 500/525 V AC 50/60 Hz 2P conforming to IEC 60947-2
5 KA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
36 KA Icu at 250 V DC 50/60 Hz 1 pole conforming to IEC 60947-2
36 KA Icu at 500 V DC 50/60 Hz 2 poles in series conforming to IEC 60947-2

Breaking capacity code F 18 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Mounting mode Fixed

Complementary
[Ui] rated insulation voltage 750 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 KV conforming to IEC 60947-2
[Ics] rated service breaking capacity 36 KA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
18 KA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
15 KA at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 KA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
5 KA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
36 KA at 250 V DC 50/60 Hz conforming to IEC 60947-2
36 KA at 500 V DC 50/60 Hz conforming to IEC 60947-2

Mechanical durability 20000 Cycles
Electrical durability 20000 Cycles at 277 V In/2
10000 Cycles at 277 V In

Power dissipation per pole 8.8 W
Mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
Downside connection Front
Connection pitch 35 Mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)

Trip unit rating 100 A at 40 °C
Long time pick-up adjustment type Ir Fixed
Long time pick-up adjustment range 1 x In
Long time delay adjustment type Fixed
Instantaneous pick-up adjustment type Ii Fixed
Instantaneous pick-up adjustment range 800 A
Earth-leakage protection Without
Width 70 Mm

Height 161 Mm
Depth 86 Mm
Net weight 1.2 Kg

Environment
Standards EN/IEC 60947-2
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating