Cont 25A AC1 2N/O+2N/C+48Vac Coil

R1,241.84

FloatOr as low as R248.37 / month interest-free, using your existing credit card. For orders over R100.00.How it works

Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,40A,24V AC coil,50Hz

Open Fact Sheet

1 in stock

Categories: , SKU: LC1D128E7

Description

 

 

 

Main

Range  TeSys

TeSys Deca

Range of product TeSys Deca
Product or component type  Contactor
Contractor application Resistive load

 

Device short name LC1D
Utilisation category

 

AC-1

AC-3

AC-3e

AC-4

 

Poles description

 

4P

 

[Ue] rated operational voltage

 

Power circuit: <= 690 V AC 25…400 Hz

Power circuit: <= 300 V DC

 

[Ie] rated operational current

 

25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

 

[Uc] control circuit voltage

 

48 V AC 50/60 Hz

 

 

Complementary

Compatibility code

 

LC1D

 

Pole contact composition

 

2 NO + 2 NC

 

Protective cover

 

With

 

[Ith] conventional free air thermal current

 

25 A (at 60 °C) for power circuit

10 A (at 60 °C) for signalling circuit

 

Irms rated making capacity

 

250 A at 440 V for power circuit conforming to IEC 60947

140 A AC for signalling circuit conforming to IEC 60947-5-1

250 A DC for signalling circuit conforming to IEC 60947-5-1

 

Rated breaking capacity

 

250 A at 440 V for power circuit conforming to IEC 60947

 

[Icw] rated short-time withstand current

 

105 A 40 °C – 10 s for power circuit 210 A 40 °C – 1 s for power circuit 30 A 40 °C – 10 min for power circuit 61 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit

 

Associated fuse rating

 

10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit

 

Average impedance

 

2.5 MOhm – Ith 25 A 50 Hz for power circuit

 

Power dissipation per pole

 

1.56 W AC-1

 

[Ui] rated insulation voltage

 

Power circuit: 690 V conforming to IEC 60947-4-1

Power circuit: 600 V CSA certified

Power circuit: 600 V UL certified

Signalling circuit: 690 V conforming to IEC 60947-1

Signalling circuit: 600 V CSA certified

Signalling circuit: 600 V UL certified

 

Overvoltage category

 

III

 

Pollution degree

 

3

 

[Uimp] rated impulse withstand voltage

 

6 KV conforming to IEC 60947

 

Safety reliability level

 

B10d = 1369863 cycles contactor with nominal load conforming-

to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming- to EN/ISO 13849-1

 

Mechanical durability

 

15 Mcycles

 

Electrical durability

 

0.8 Mcycles 25 A AC-1 at Ue <= 440 V

 

Control circuit type

 

AC at 50/60 Hz standard

 

Coil technology

 

Without built-in suppressor module

 

Control circuit voltage limits

 

0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz

0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz

1…1.1 Uc (60…70 °C):operational AC 50/60 Hz

 

Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)

70 VA 50 Hz cos phi 0.75 (at 20 °C)

 

Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)

7 VA 50 Hz cos phi 0.3 (at 20 °C)

 

Heat dissipation 2…3 W at 50/60 Hz

 

 

Operating time

 

 

 

12…22 ms closing

4…19 ms opening

 

Maximum operating rate

 

3600 Cyc/H 60 °C

 

Connections – terminals

 

Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without- cable end

Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with- out cable end

Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- cable end

Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with- cable end

Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without- cable end

Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without- cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- out cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with- out cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- cable end

Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible- with cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without- cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without- cable end

Power circuit: screw connection 2 1…25 mm² – cable stiffness: solid without ca- ble end

 

Tightening torque

 

Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver- pozidriv No 2

Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver- pozidriv No 2

 

Auxiliary contact composition

 

1 NO + 1 NC

 

Auxiliary contacts type

 

Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1

 

Signalling circuit frequency

 

25…400 Hz

 

Minimum switching voltage

 

17 V for signalling circuit

 

Minimum switching current

 

5 MA for signalling circuit

 

Insulation resistance

 

> 10 MOhm for signalling circuit

 

Non-overlap time

 

1.5 Ms on de-energisation between NC and NO contact

1.5 Ms on energisation between NC and NO contact

 

Mounting support

 

Rail

Plate

 

 

 

 

 

Environment

 

Standards

 

CSA C22.2 No 14

EN 60947-4-1

EN 60947-5-1

IEC 60947-4-1

IEC 60947-5-1

UL 508

IEC 60335-1

 

Product certifications

 

GL[RETURN]CSA[RETURN]GOST[RETURN]RINA[RETURN]LROS (Lloyds reg- ister of shipping)[RETURN]UL[RETURN]DNV[RETURN]BV[RETURN]CCC[RE- TURN]CB

 

IP degree of protection

 

IP20 front face conforming to IEC 60529

 

Protective  treatment

 

TH conforming to IEC 60068-2-30

 

Climatic withstand

 

Conforming to IACS E10 exposure to damp heat

conforming to IEC 60947-1 Annex Q category D exposure to damp heat

 

Permissible ambient air temperature around the de- vice

 

-40…60 °C

60…70 °C with derating

 

Operating altitude

 

0…3000 m

 

Fire resistance

 

850 °C conforming to IEC 60695-2-1

 

Flame retardance

 

V1 conforming to UL 94

 

Mechanical robustness

 

Vibrations contactor open (2 Gn, 5…300 Hz)

Vibrations contactor closed (4 Gn, 5…300 Hz)

Shocks contactor closed (15 Gn for 11 ms)

Shocks contactor open (10 Gn for 11 ms)

 

Height

 

158 Mm
Width 120 Mm
Depth 136 Mm
Net weight 25 Kg

 

 

 

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.800 Cm
Package 1 Width 9.500 Cm
Package 1 Length 12.000 Cm
Package 1 Weight 395.000Kg
Unit Type of Package 2 S02
Number of Units in Package 2 16
Package 2 Height 15.000 Cm
Package 2 Width 30.000Cm
Package 2 Length 40.000Cm
Package 2 Weight 6.803 Kg
Unit Type of Package 3 P06
Number of Units in Package 3 256
Package 3 Height 75.000 Cm
Package 3 Width 60.000 Cm
Package 3 Length 80.000 Cm
Package 3 Weight 116.848

 

Additional information

Weight 0.51 kg
Dimensions 15.8 × 12 × 13.6 cm