Description
LC1D80F7
Main
| Range | TeSys TeSys Deca |
| Range of product | TeSys Deca |
| Product or component type | Contactor |
| Contractor application | Motor control Resistive load
|
| Device short name | LC1D |
| Utilisation category
| AC-4 AC-1 AC-3 AC-3e
|
| Poles description
| 3P
|
| [Ue] rated operational voltage
| Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC
|
| [Ie] rated operational current
| 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 80 A (at <60 °C) at <= 440 V AC-3e for power circuit
|
| [Uc] control circuit voltage
| 110 V AC 50/60 Hz
|
Complementary
| Motor power kW
| 22 KW at 220…230 V AC 50/60 Hz (AC-3) 37 KW at 380…400 V AC 50/60 Hz (AC-3) 45 KW at 415…440 V AC 50/60 Hz (AC-3) 55 KW at 500 V AC 50/60 Hz (AC-3) 45 KW at 660…690 V AC 50/60 Hz (AC-3) 15 KW at 400 V AC 50/60 Hz (AC-4) 22 KW at 220…230 V AC 50/60 Hz (AC-3e) 37 KW at 380…400 V AC 50/60 Hz (AC-3e) 45 KW at 415…440 V AC 50/60 Hz (AC-3e) 55 KW at 500 V AC 50/60 Hz (AC-3e) 45 KW at 660…690 V AC 50/60 Hz (AC-3e)
|
| Motor power hp
| 7.5 Hp at 120 V AC 50/60 Hz for 1 phase motors 15 Hp at 230/240 V AC 50/60 Hz for 1 phase motors 30 Hp at 200/208 V AC 50/60 Hz for 3 phases motors 30 Hp at 230/240 V AC 50/60 Hz for 3 phases motors 60 Hp at 460/480 V AC 50/60 Hz for 3 phases motors 60 Hp at 575/600 V AC 50/60 Hz for 3 phases motors
|
| Compatibility code
| LC1D
|
| Pole contact composition
| 3 NO
|
| Protective cover
| With
|
| [Ith] conventional free air thermal current
| 10 A (at 60 °C) for signalling circuit 125 A (at 60 °C) for power circuit
|
| Irms rated making capacity
| 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947
|
| Rated breaking capacity
| 1100 A at 440 V for power circuit conforming to IEC 60947
|
| [Icw] rated short-time withstand current
| 640 A 40 °C – 10 s for power circuit 990 A 40 °C – 1 s for power circuit 135 A 40 °C – 10 min for power circuit 320 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit
|
| Associated fuse rating
| 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit
|
| Average impedance
| 0.8 MOhm – Ith 125 A 50 Hz for power circuit
|
| Power dissipation per pole
| 5.1 W AC-3 12.5 W AC-1 5.1 W AC-3e
|
| [Ui] rated insulation voltage
| Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1
|
| Overvoltage category
| III
|
| Pollution degree
| 3
|
| [Uimp] rated impulse withstand voltage
| 8 KV conforming to IEC 60947
|
| Safety reliability level
| B10d = 1369863 cycles contactor with nominal load conforming- to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming- to EN/ISO 13849-1
|
| Mechanical durability
| 6 Mcycles
|
| Electrical durability
| 1.4 Mcycles 80 A AC-1 at Ue <= 440 V 1.45 Mcycles 65 A AC-3 at Ue <= 440 V 1.45 Mcycles 65 A AC-3e at Ue <= 440 V
|
| Control circuit type
| AC at 50/60 Hz standard
|
| Coil technology
| Without built-in suppressor module
|
| Control circuit voltage limits
| 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz 1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
|
| Inrush power in VA | 245 VA 60 Hz cos phi 0.75 (at 20 °C) 245 VA 50 Hz cos phi 0.75 (at 20 °C)
|
| Hold-in power consumption in VA | 26 VA 60 Hz cos phi 0.3 (at 20 °C) 26 VA 50 Hz cos phi 0.3 (at 20 °C)
|
| Heat dissipation | 6…10 W at 50/60 Hz
|
| Operating time
| 20…35 ms closing 6…20 ms opening
|
| Maximum operating rate
| 3600 Cyc/H 60 °C
|
| Maximum operating rate
| 3600 Cyc/H at 60 °C
|
| Connections – terminals
| Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with- cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- out cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with- out cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without- cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without- cable end Power circuit: screw connection 1 1…35 mm² – cable stiffness: flexible without ca- ble end Power circuit: screw connection 2 1…25 mm² – cable stiffness: flexible without ca- ble end Power circuit: screw connection 1 1…35 mm² – cable stiffness: flexible with ca- ble end Power circuit: screw connection 2 1…25 mm² – cable stiffness: flexible with ca- ble end Power circuit: screw connection 1 1…35 mm² – cable stiffness: solid without ca- ble end Power circuit: screw connection 2 1…25 mm² – cable stiffness: solid without ca- ble end
|
| Tightening torque
| Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver- flat Ø 6 mm Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver- Philips No 2 Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 m- m² hexagonal screw head 4 mm Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 m- m² hexagonal screw head 4 mm Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver- pozidriv No 2 Power circuit: 2.5 N.m – on EverLink BTR screw connectors – with screwdriver- pozidriv No 2
|
| Auxiliary contact composition
| 1 NO + 1 NC
|
| Auxiliary contacts type
| Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
|
| Signalling circuit frequency
| 25…400 Hz
|
| Minimum switching voltage
| 17 V for signalling circuit
|
| Minimum switching current
| 5 MA for signalling circuit
|
| Insulation resistance
| > 10 MOhm for signalling circuit
|
| Non-overlap time
| 1.5 Ms on de-energisation between NC and NO contact 1.5 Ms on energisation between NC and NO contact
|
| Mounting support
| Rail Plate
|
| Environment |
| Standards
| CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1
|
| Product certifications
| GL[RETURN]CSA[RETURN]GOST[RETURN]RINA[RETURN]LROS (Lloyds reg- ister of shipping)[RETURN]UL[RETURN]DNV[RETURN]BV[RETURN]CCC[RE- TURN]CB
|
| IP degree of protection
| IP20 front face conforming to IEC 60529
|
| Protective treatment
| TH conforming to IEC 60068-2-30
|
| Climatic withstand
| Conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat
|
| Permissible ambient air temperature around the de- vice
| -40…60 °C 60…70 °C with derating
|
| Operating altitude
| 0…3000 m
|
| Fire resistance
| 850 °C conforming to IEC 60695-2-1
|
| Flame retardance
| V1 conforming to UL 94
|
| Mechanical robustness
| Vibrations contactor open (2 Gn, 5…300 Hz) Vibrations contactor closed (4 Gn, 5…300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (10 Gn for 11 ms)
|
| Height
| 127 Mm |
| Width | 85 Mm |
| Depth | 130 Mm |
| Net weight | 1.59 Kg |
Packing Units
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 10.000 Cm |
| Package 1 Width | 13.500 Cm |
| Package 1 Length | 14.000 Cm |
| Package 1 Weight | 1.555 Kg |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 5 |
| Package 2 Height | 15.000 Cm |
| Package 2 Width | 30.000 Cm |
| Package 2 Length | 40.000 Cm |
| Package 2 Weight | 8.018 Kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 80 |
| Package 3 Height | 75.000 Cm |
| Package 3 Width | 80.000Cm |
| Package 3 Length | 60.000 Cm |
| Package 3 Weight | 136.288 Kg |