Cont AC3 115A + 110V Coil

R9,119.24

FloatOr as low as R1,823.85 / month interest-free, using your existing credit card. For orders over R100.00.How it works

TeSys D contactor. 3P(3 NO). AC-3. <= 440 V 115 A. 110 VAC 50/60 Hz coil

Open Fact Sheet

3 in stock

Categories: , SKU: LC1D115F7

Description

 

 

 

Main

Range  TeSys

TeSys Deca

Range of product TeSys Deca
Product or component type  Contactor
Contractor application Motor control

Resistive load

 

Device short name LC1D
Utilisation category

 

AC-3

AC-3e

AC-4

AC-1

 

Poles description

 

3P

 

[Ue] rated operational voltage

 

Power circuit: <= 1000 V AC 25…400 Hz

Power circuit: <= 300 V DC

 

[Ie] rated operational current

 

200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

 

[Uc] control circuit voltage

 

110 V AC 50/60 Hz

 

 

Complementary

Motor power kW

 

30 KW at 220…230 V AC 50/60 Hz (AC-3) 55 KW at 380…400 V AC 50/60 Hz (AC-3) 59 KW at 415…440 V AC 50/60 Hz (AC-3) 75 KW at 500 V AC 50/60 Hz (AC-3) 80 KW at 660…690 V AC 50/60 Hz (AC-3) 65 KW at 1000 V AC 50/60 Hz (AC-3) 18.5 KW at 400 V AC 50/60 Hz (AC-4) 30 KW at 220…230 V AC 50/60 Hz (AC-3e) 55 KW at 380…400 V AC 50/60 Hz (AC-3e) 59 KW at 415…440 V AC 50/60 Hz (AC-3e) 75 KW at 500 V AC 50/60 Hz (AC-3e) 80 KW at 660…690 V AC 50/60 Hz (AC-3e) 65 KW at 1000 V AC 50/60 Hz (AC-3e)

 

Motor power hp

 

30 Hp at 200/208 V AC 50/60 Hz for 3 phases motors

40 Hp at 230/240 V AC 50/60 Hz for 3 phases motors 75 Hp at 460/480 V AC 50/60 Hz for 3 phases motors 100 Hp at 575/600 V AC 50/60 Hz for 3 phases motors

 

Compatibility code

 

LC1D

 

Pole contact composition

 

3 NO

 

Protective cover

 

With

 

[Ith] conventional free air thermal current

 

200 A (at 60 °C) for power circuit

 

Irms rated making capacity

 

1260 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1

 

Rated breaking capacity

 

1100 A at 440 V for power circuit conforming to IEC 60947

 

[Icw] rated short-time withstand current

 

250 A 40 °C – 10 min for power circuit 550 A 40 °C – 1 min for power circuit 950 A 40 °C – 10 s for power circuit 1100 A 40 °C – 1 s for power circuit 100 A – 1 s for signalling circuit

120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit

 

Associated fuse rating

 

250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit

 

Average impedance

 

0.6 MOhm – Ith 200 A 50 Hz for power circuit

 

Power dissipation per pole

 

24 W AC-1

7.9 W AC-3

7.9 W AC-3e

 

[Ui] rated insulation voltage

 

Power circuit: 600 V CSA certified

Power circuit: 600 V UL certified

Power circuit: 1000 V conforming to IEC 60947-4-1

Signalling circuit: 690 V conforming to IEC 60947-1

Signalling circuit: 600 V CSA certified

Signalling circuit: 600 V UL certified

 

Overvoltage category

 

III

 

Pollution degree

 

3

 

[Uimp] rated impulse withstand voltage

 

8 KV conforming to IEC 60947

 

Safety reliability level

 

B10d = 1369863 cycles contactor with nominal load conforming-

to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming- to EN/ISO 13849-1

 

Mechanical durability

 

8 Mcycles

 

Electrical durability

 

0.8 Mcycles 200 A AC-1 at Ue <= 440 V

0.95 Mcycles 115 A AC-3 at Ue <= 440 V

0.95 Mcycles 115 A AC-3e at Ue <= 440 V

 

Control circuit type

 

AC at 50/60 Hz standard

 

Coil technology

 

Without built-in suppressor module

 

Control circuit voltage limits

 

0.3…0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz

0.8…1.15 Uc (-40…55 °C):operational AC 50/60 Hz

1…1.15 Uc (55…70 °C):operational AC 50/60 Hz

 

Inrush power in VA 280…350 VA 60 Hz cos phi 0.8 (at 20 °C)

280…350 VA 50 Hz cos phi 0.8 (at 20 °C)

 

Hold-in power consumption in VA 2…18 VA 60 Hz cos phi 0.3 (at 20 °C)

2…18 VA 50 Hz cos phi 0.3 (at 20 °C)

 

Heat dissipation 3…8 W at 50/60 Hz

 

 

Operating time

 

 

 

6…20 ms opening

20…50 ms closing

 

Maximum operating rate

 

2400 Cyc/H 60 °C

 

Maximum operating rate

 

2400 Cyc/H at 60 °C

 

Connections – terminals

 

Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with- cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- out cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with- out cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with- cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without- cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without- cable end

Power circuit: screw connection 1 1…35 mm² – cable stiffness: flexible without ca- ble end

Power circuit: screw connection 2 1…25 mm² – cable stiffness: flexible without ca- ble end

Power circuit: screw connection 1 1…35 mm² – cable stiffness: flexible with ca- ble end

Power circuit: screw connection 2 1…25 mm² – cable stiffness: flexible with ca- ble end

Power circuit: screw connection 1 1…35 mm² – cable stiffness: solid without ca- ble end

Power circuit: screw connection 2 1…25 mm² – cable stiffness: solid without ca- ble end

 

Tightening torque

 

Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2

Power circuit: 12 N.m – on connector hexagonal screw head 4 mm

Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver- pozidriv No 2

Power circuit: 2.5 N.m – on EverLink BTR screw connectors – with screwdriver- pozidriv No 2

 

Auxiliary contact composition

 

1 NO + 1 NC

 

Auxiliary contacts type

 

Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1

 

Signalling circuit frequency

 

25…400 Hz

 

Minimum switching voltage

 

17 V for signalling circuit

 

Minimum switching current

 

5 MA for signalling circuit

 

Insulation resistance

 

> 10 MOhm for signalling circuit

 

Non-overlap time

 

1.5 Ms on de-energisation between NC and NO contact

1.5 Ms on energisation between NC and NO contact

 

Mounting support

 

Rail

Plate

 

 

 

 

 

Environment

 

Standards

 

CSA C22.2 No 14

EN 60947-4-1

EN 60947-5-1

IEC 60947-4-1

IEC 60947-5-1

UL 508

IEC 60335-1

 

Product certifications

 

GL[RETURN]CSA[RETURN]GOST[RETURN]RINA[RETURN]LROS (Lloyds reg- ister of shipping)[RETURN]UL[RETURN]DNV[RETURN]BV[RETURN]CCC[RE- TURN]CB

 

IP degree of protection

 

IP20 front face conforming to IEC 60529

 

Protective  treatment

 

TH conforming to IEC 60068-2-30

 

Climatic withstand

 

Conforming to IACS E10 exposure to damp heat

conforming to IEC 60947-1 Annex Q category D exposure to damp heat

 

Permissible ambient air temperature around the de- vice

 

-40…60 °C

60…70 °C with derating

 

Operating altitude

 

0…3000 m

 

Fire resistance

 

850 °C conforming to IEC 60695-2-1

 

Flame retardance

 

V1 conforming to UL 94

 

Mechanical robustness

 

Vibrations contactor open (2 Gn, 5…300 Hz)

Vibrations contactor closed (4 Gn, 5…300 Hz)

Shocks contactor closed (15 Gn for 11 ms)

Shocks contactor open (10 Gn for 11 ms)

 

Height

 

158 Mm
Width 120 Mm
Depth 136 Mm
Net weight 2.5 Kg

 

 

 

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.500 Cm
Package 1 Width 17.500 Cm
Package 1 Length 21.500 Cm
Package 1 Weight 2.495 Kg
Unit Type of Package 2 P02
Number of Units in Package 2 27
Package 2 Height 75.000 Cm
Package 2 Width 60.000 Cm
Package 2 Length 80.000 Cm
Package 2 Weight 80.311 Kg

 

Additional information

Weight 0.51 kg
Dimensions 15.8 × 12 × 13.6 cm