Cont Rev 12A AC3+220V Coil

R3,380.68

FloatOr as low as R676.14 / month interest-free, using your existing credit card. For orders over R100.00.How it works

Reversing Contactor, TeSys Deca, 3P(3NO), AC-3, <=440V, 12A, 230V AC 50/60Hz coil, screw clamp terminals

10 in stock

Categories: , SKU: LC2D12P7

Description

 

Main

Range TeSys

TeSys Deca

Product name TeSys D

TeSys Deca

Device short name LC2D
Contactor application Motor control

Resistive load

Utilisation category AC-1

AC-3

AC-3e

Device presentation Preassembled with reversing power busbar
Poles description 3P
Pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz

Power circuit: <= 300 V DC

[Ie] rated operational current 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

Motor power kW 3 KW at 220…230 V AC 50 Hz

5.5 KW at 380…400 V AC 50 Hz

5.5 KW at 415 V AC 50 Hz

5.5 KW at 440 V AC 50 Hz

7.5 KW at 500 V AC 50 Hz

7.5 KW at 660…690 V AC 50 Hz

Motor power hp 1 Hp at 115 V AC 60 Hz for 1 phase motors

2 Hp at 230/240 V AC 60 Hz for 1 phase motors

3 Hp at 200/208 V AC 60 Hz for 3 phases motors

3 Hp at 230/240 V AC 60 Hz for 3 phases motors

7.5 Hp at 460/480 V AC 60 Hz for 3 phases motors

10 Hp at 575/600 V AC 60 Hz for 3 phases motors

 Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 230 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 KV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit

25 A (at 60 °C) for power circuit

Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947

140 A AC for signalling circuit conforming to IEC 60947-5-1

250 A DC for signalling circuit conforming to IEC 60947-5-1

Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 30 A 40 °C – 10 min for power circuit

61 A 40 °C – 1 min for power circuit

105 A 40 °C – 10 s for power circuit

210 A 40 °C – 1 s for power circuit

100 A – 1 s for signalling circuit

120 A – 500 ms for signalling circuit

140 A – 100 ms for signalling circuit

Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1

40 A gG at <= 690 V coordination type 1 for power circuit

25 A gG at <= 690 V coordination type 2 for power circuit

Average impedance 2.5 MOhm – Ith 25 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1

Power circuit: 600 V CSA certified

Power circuit: 600 V UL certified

Signalling circuit: 690 V conforming to IEC 60947-1

Signalling circuit: 600 V CSA certified

Signalling circuit: 600 V UL certified

Electrical durability 2 Mcycles 9 A AC-3 at Ue <= 440 V

0.8 Mcycles 25 A AC-1 at Ue <= 440 V

2 Mcycles 9 A AC-3e at Ue <= 440 V

Power dissipation per pole 1.56 W AC-1

0.36 W AC-3

0.36 W AC-3e

Protective cover With
Interlocking type Mechanical
Mounting support Plate

Rail

Standards CSA C22.2 No 14

EN 60947-4-1

EN 60947-5-1

IEC 60947-4-1

IEC 60947-5-1

UL 508

IEC 60335-1

Product certifications DNV[RETURN]CSA[RETURN]CCC[RETURN]UL[RETURN]GL[RETURN]LROS (Lloyds register of shipping)[RETURN]BV[RETURN]RINA[RETURN] GOST[RETURN]UKCA
Connections – terminals Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end

Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end

Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end

Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end

Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid

Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid

Tightening torque Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriverpozidriv No 2

Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriverpozidriv No 2

Operating time 12…22 ms closing

4…19 ms opening

Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability 15 Mcycles
Maximum operating rate 3600 Cyc/H 60 °C

 

Complementary

Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz

0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz

0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz

1…1.1 Uc (60…70 °C):operational AC 50/60 Hz

Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)

70 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)

7 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation 2…3 W at 50/60 Hz
Auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching current 5 MA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 Ms on de-energisation between NC and NO contact

1.5 Ms on energisation between NC and NO contact

Insulation resistance > 10 MOhm for signalling circuit

 

Environment

 

IP degree of protection IP20 front face conforming to IEC 60529
Climatic withstand Conforming to IACS E10

conforming to IEC 60947-1 Annex Q category D

Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -40…60 °C

60…70 °C with derating

Ambient air temperature for storage -60…80 °C
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 confirming to IEC 60695-2-1
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)

Vibrations contactor closed (4 Gn, 5…300 Hz)

Shocks contactor open (10 Gn for 11 ms)

Shocks contactor closed (15 Gn for 11 ms)

Height 77 Mm
Width 90 Mm
Depth 86 Mm
Net weight 0.697 Kg

 

Packing Units

 

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 13.800 Cm
Package 1 Width 9.300 Cm
Package 1 Length 11.300 Cm
Package 1 Weight 808.000 Kg
Unit Type of Package 2 S02
Number of Units in Package 2 6
Package 2 Height 15.000 Cm
Package 2 Width 30.000 Cm
Package 2 Length 40.000 Cm
Package 2 Weight 5.146 Kg

 

Additional information

Weight 0.48 kg
Dimensions 7.4 × 4.5 × 8 cm