EASYPACT TVS CONTACTOR 3P 3NO AC3 6A 240VAC COIL

R149.18

EasyPact TVS contactor 3P(3 NO) –
AC-3 – <= 440 V 6A – 240 V AC coil

Pay over 3 EQUAL zero-interest instalments of R49.73 with PayJustNow.
Find out how...

HOW IT WORKS

PayJustNow allows you to pay for your purchase over 3 payments with 0% interest and no fees. Pay a third at checkout and receive your goods immediately. The remaining two instalments are debited on your selected instalment dates.

Browse online or in-store and proceed to checkout

Choose PayJustNow as your payment method

Create your account and receive an instant approval decision

Complete your transaction

WHAT YOU WILL NEED

Be over 18 years old

Be a South African resident

Have a debit or credit card

Have a valid email address

0% INTEREST. 3 PAYMENTS. NO STRESS.

WHY PAY ANY OTHER WAY?

9 in stock

Or as low as R29.84 over 5 months interest free, using your credit card. For orders over R1.00.How it works
Category: SKU: LC1E0601U5 Brand:

Description

Main
Range Easy TeSys
Range of product Easy TeSys Control
Product or component type Contactor
Device short name LC1E
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-3e
AC-1
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current 6 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
6 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
20 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 240 V AC 50 Hz

Complementary
Motor power kW 1.1 kW at 220…230 V AC 50/60 Hz
2.2 kW at 380…400 V AC 50/60 Hz
2.2 kW at 415 V AC 50/60 Hz
2.2 kW at 440 V AC 50/60 Hz
3 kW at 500 V AC 50/60 Hz
3 kW at 660…690 V AC 50/60 Hz
Pole contact composition 3 NO
[Ith] conventional free air thermal
current
20 A (at 55 °C) for power circuit
Irms rated making capacity 60 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity 48 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand
current
80 A 40 °C – 10 s for power circuit
45 A 40 °C – 60 s for power circuit
20 A 40 °C – 600 s for power circuit
Associated fuse rating 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC
60947-5-1
12 A gG at <= 690 V coordination type 1 for power circuit
Average impedance 2.5 mOhm – Ith 20 A 50 Hz for power circuit
Power dissipation per pole 0.09 W AC-3
1 W AC-1
[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
overvoltage category III

pollution degree 3
[Uimp] rated impulse withstand
voltage
6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability 10000000 cycles
Electrical durability 1400000 cycles AC-3
150000 cycles AC-1
Control circuit type AC at 50 Hz
Control circuit voltage limits 0.85…1.1 Uc (-5…55 °C):operational 50 Hz
0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA 95 VA 50 Hz cos phi 0.75 (at 20 °C)
95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 8.3 VA 50 Hz cos phi 0.3 (at 20 °C)
8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W for control circuit
Operating time 12…22 ms on closing
4…19 ms on opening
Maximum operating rate 1800 cyc/h 60 °C
Connections – terminals Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable
end
Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with
cable end
Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable
end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable
end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without
cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without
cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable
end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with
cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without
cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without
cable end
Tightening torque Power circuit: 1.2 N.m
Control circuit: 1.2 N.m

Auxiliary contact composition 1 NC
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting support DIN rail
Plate
Environment
Standards IEC 60947-4-1
IEC 60947-5-1
IEC 60947-1
Product certifications CE
EAC
IP degree of protection IP2X conforming to IEC 60529
Protective treatment TH (pollution degree 3) conforming to IEC 60068-2-30

Permissible ambient air
temperature around the device
-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Mechanical robustness Vibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor open (7 Gn for 11 ms)
Shocks contactor closed (10 Gn for 11 ms)
Height 74 mm
Width 45 mm
Depth 80 mm
Net weight 0.3 kg