LIMIT SWITCH

R1,611.66

Limit switch, Limit switches XC Standard, XCKM, thermoplastic roller lever, 1NC+1 NO, snap action, M20

Pay over 3 EQUAL zero-interest instalments of R537.22 with PayJustNow.
Or pay over 12 instalments of with PayJustNow.
Find out how...

Your flexible payment provider.

Example payment for

x 3
0% interest, zero fees.
Pay in 3
x 12
28% interest, plus fees.
Total Payment
Pay in 12

How does PayJustNow work?

You can complete sign-up in under 2 minutes - no need to leave your cart!

3 in stock

Or as low as R322.34 over 5 months interest free, using your credit card. For orders over R1.00.How it works
Categories: , SKU: XCKM115H29 Brand:

Description

Main
Range of product Telemecanique Limit switches XC Standard
Series name Standard format
Product or component
type

Limit switch
Device short name XCKM
Body type Fixed
Head type Rotary head
Material Metal
Body material Zamak
Fixing mode By the body
Movement of operating
head

Rotary

Type of operator Spring return roller lever thermoplastic
Type of approach Lateral approach, 2 directions
Cable entry 3 entries tapped for M20 x 1.5 cable gland, cable

outer diameter: 7…13 mm

Number of poles 2
Contacts type and
composition

1 NC + 1 NO
Contact operation Snap action

Complementary
Switch actuation By 30° cam
Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm2
Contacts insulation form Zb
Number of steps 1
Positive opening With
Positive opening minimum torque 0.25 N.m
Minimum torque for tripping 0.1 N.m
Minimum actuation speed 0.01 m/min
Maximum actuation speed 1.5 m/s
Contact code designation A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current 10 A AC
[Ui] rated insulation voltage 300 V conforming to UL 508

500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage 6 KV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Short-circuit protection 10 A cartridge fuse, type gG
Electrical durability 5000000 Cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/

mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 Cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/
mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/
mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

Mechanical durability 15000000 cycles
Width 64 mm
Height 64 mm

Depth 30 mm
Net weight 0.28 kg
Terminals description ISO n°1 (21-22)NC
(13-14)NO

Environment
Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection IP66 conforming to IEC 60529
IK degree of protection IK05 conforming to IEC 62262
Electrical shock protection class Class I conforming to IEC 61140
Class I conforming to NF C 20-030

Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…70 °C
Protective treatment TC
Product certifications CSA[RETURN]UL[RETURN]CCC
Standards IEC 60947-5-1
IEC 60204-1
IEC 60947-5-1
UL 508
IEC 60204-1
CSA C22.2 No 14