Description
Commercial data
Item number | 2866310 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | 090 |
Product key | CMPT13 |
Catalog page | Page 175 (C-6-2013) |
GTIN | 4046356046657 |
Weight per piece (incl. packing) | 1 554 g |
Weight per piece (excl. packing) | 1 400 g |
Customs tariff number | 85044095 |
Country of origin | CN |
TRIO-PS/1AC/24DC/10 – Power supply unit
2866323 | My ID: PS10010
Technical data
Input data
AC operation
Parameter | Specification |
Nominal Input Voltage Range | 100 V AC … 240 V AC |
Input Voltage Range | 85 V AC … 264 V AC (Derating < 90 V AC: 2.5 %/V) |
Derating | < 90 V AC: 2.5 %/V |
Electric Strength | Max. 300 V AC |
Voltage Type of Supply Voltage | AC |
Inrush Current | < 15 A |
Inrush Current Integral (I2 t) | 0.7 A2 s |
AC Frequency Range | 45 Hz … 65 Hz |
Mains Buffering Time | > 24 ms (120 V AC)
> 24 ms (230 V AC) |
Current Consumption | 3 A (100 V AC)
1.5 A (240 V AC) |
Nominal Power Consumption | 272 VA |
Protective Circuit | Transient surge protection; Varistor |
Power Factor (cos phi) | 0.99 |
Typical Response Time | < 1 s |
Input Fuse | 6.3 A (slow-blow, internal) |
Permissible Backup Fuse | B6 B10 B16 |
Recommended Breaker for Input Protection | 10 A … 16 A (Characteristics B, C, D, K) |
Discharge Current to PE | < 3.5 mA |
Output data
Efficiency | 89 % (for 230 V AC and nominal values) |
Output characteristic | U/I |
Nominal output voltage | 24 V DC ±1% |
Setting range of output voltage (USet) | 22.5 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted) |
Nominal output current (IOUT) | 10 A (UOUT = 24 V DC) |
Derating | 55 °C … 70 °C (2.5 %/K |
Feedback voltage resistance | 35 V DC |
Protection against overvoltage (OVP) | < 35 V DC |
Max. capacitive load | Unlimited |
Active current limitation | Approx. 14 A (for short-circuit) |
Control deviation | < 1% (change in load, static 10% … 90%)
< 2% (change in load, dynamic 10% … 90%) < 0.1% (change in input voltage ±10%) |
Residual ripple | < 10 mVPP |
Output power | 240 W |
Peak switching voltages nominal load | < 50 mVPP |
TRIO-PS/1AC/24DC/10 – Power supply unit
2866323 | My ID: PS10010
Maximum No-load Power Dissipation | 6.7 W |
Power Loss at Nominal Load (Max.) | 30 W |
Rise Time | < 2 ms (UOUT 10% to 90%) |
Connection in Parallel | Yes, for redundancy and increased capacity |
Connection in Series | Yes |
Connection data
Input
Connection method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 9 mm |
Screw thread | M2.5 |
Tightening torque, min | 0.4 Nm |
Tightening torque, max | 0.5 Nm |
Output
Connection method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section, AWG min | 24 |
Conductor cross section AWG min. | 14 |
Stripping length | 9 mm |
Screw thread | M2.5 |
Tightening torque, min | 0.4 Nm |
Tightening torque, max | 0.5 Nm |
Signaling
Types of signaling | LED |
Operating voltage display | Green LED |
Signal output
Status display | “DC OK” LED green |
Note on status | UOUT < 0.9 x UN : LED flashing |
Electrical properties
Insulation voltage input/output | 4 kV AC (type test)
2 kV AC (routine test) |
Insulation voltage output / PE | 500 V DC (type test) |
TRIO-PS/1AC/24DC/10 – Power supply unit
Insulation voltage input / PE | 2 kV AC (type test)
2 kV AC (routine test) |
Product properties
Product type | Power supply |
Product family | TRIO POWER |
MTBF (IEC 61709, SN 29500) | > 981000 h (40 °C) |
Insulation characteristics
Protection class | I (with PE connection) |
Overvoltage category | III |
Degree of pollution | 2 |
Dimensions
Dimensional drawing | |
Width | 60 mm |
Height | 130 mm |
Depth | 152.5 mm |
Installation dimensions
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Mounting
Mounting type | DIN rail mounting |
Assembly note | Alignable: horizontally 0 mm, vertically 50 mm |
Mounting position | Horizontal DIN rail NS 35, EN 60715 |
With protective coating | No |
Material specifications
Housing material | Metal |
Type of housing | Steel sheet, zinc-plated |
Side element version | Aluminum |
Environmental and real-life conditions
Ambient conditions
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C … 70 °C
(> 55° C derating : 2.5%/K) |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity | ≤ 95 % (at 25 °C, non-condensing) |
TRIO-PS/1AC/24DC/10 – Power supply unit
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2- 27) |
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz … 150 Hz, 2.3g, 90 min |
Standards and regulations
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Standard – Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 |
Standard – Safety extra-low voltage | EN 60950-1 (SELV)
EN 60204 (PELV) |
Standard – Safe isolation | DIN VDE 0100-410 |
Approvals
UL approvals | UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1 |
Conformity/Approvals
SIL in accordance with IEC 61508 | 0 |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
EMC Requirements for Noise Emission | EN 61000-6-3
EN 61000-6-4 |
EMC Requirements for Noise Immunity | EN 61000-6-1
EN 61000-6-2 |
Electromagnetic Compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
Standards/Regulations | EN 61000-4-2 |
Electrostatic discharge
Contact discharge | 6 kV (Test Level 3 |
Discharge in air | 8 kV (Test Level 3) |
Comments | Criterion A |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Electromagnetic HF field
Frequency Range | 80 MHz … 1 GHz |
Test Field Strength | 10 V/m |
Frequency Range | 1 GHz … 2 GHz |
Test Field Strength | 10 V/m |
TRIO-PS/1AC/24DC/10 – Power supply unit
Frequency Range | 2 GHz … 3 GHz |
Test Field Strength | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Fast transients (burst)
Input | 4 kV (Test Level 4 – asymmetrical) |
Output | 4 kV (Test Level 4 – asymmetrical) |
Signal | 2 kV (Test Level 3 – asymmetrical) |
Comments | Criterion A |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Surge voltage load (surge)
Input | 1 kV (Test Level 2 – symmetrical)
2 kV (Test Level 3 – asymmetrical) |
Output | 0.5 kV (Test Level 1 – symmetrical)
0.5 kV (Test Level 1 – asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Conducted interference
Frequency Range | 0.15 MHz … 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Conducted interference
Frequency Range | 0.15 MHz … 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Voltage dips
Standards/regulations | EN 61000-4-11 |
Emitted interference
Standards/regulations | EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
TRIO-PS/1AC/24DC/10 – Power supply unit
Classifications
ECLASS
ECLASS-11.0 | 27040701 |
ECLASS-12.0 | 27040701 |
ECLASS-13.0 | 27040701 |
ETIM
ETIM 8.0 | EC002540 |
UNSPSC
UNSPSC 21.0 | 39121000 |
TRIO-PS/1AC/24DC/10 – Power supply unit
Environmental product compliance
EU RoHS
Fulfills EU RoHS substance requirements | Yes |
Exemption | 7(a), 7(c)-I |
China RoHS
Environment friendly use period (EFUP) | EFUP-25
An article-related China RoHS declaration table can be found in the download area for the respective article under “Manufacturer declaration”. For all articles with EFUP-E, no China RoHS declaration table issued and required |
EU REACH SVHC
REACH candidate substance (CAS No.) | Lead(CAS: 7439-92-1) |
SCIP | 061338d1-7936-40eb-b79e-d37d0dc74e3b |
TRIO-PS/1AC/24DC/10 – Power supply unit
Accessories
UWA 182/52 – Mounting adapter
Universal wall adapter for securely mounting the device in the event of strong vibrations. The device is screwed directly onto the mounting surface. The universal wall adapter is attached on the top/bottom.
UTA 107 – DIN rail adapter
Universal DIN rail adapter, for screwing on switchgear
TRIO-PS/1AC/24DC/10 – Power supply unit
PLT-SEC-T3-230-FM-UT – Type 3 surge protection device
Type 2/3 surge protection, consisting of protective plug and base element with screw connection. For single-phase power supply network with integrated status indicator and remote signaling. Nominal voltage: 230 V AC/DC
PLT-SEC-T3-24-FM-UT – Type 3 surge protection device
Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage: 24 V AC/DC