SIEMENS CONTACTOR 3P 9A 1NO

R265.02

3P Power Contactor AC3:9A 1NO AC230V 50Hz Main circuit: Screw Auxiliary circuit: Screw

Pay over 3 EQUAL zero-interest instalments of R88.34 with PayJustNow.
Find out how...

HOW IT WORKS

PayJustNow allows you to pay for your purchase over 3 payments with 0% interest and no fees. Pay a third at checkout and receive your goods immediately. The remaining two instalments are debited on your selected instalment dates.

Browse online or in-store and proceed to checkout

Choose PayJustNow as your payment method

Create your account and receive an instant approval decision

Complete your transaction

WHAT YOU WILL NEED

Be over 18 years old

Be a South African resident

Have a debit or credit card

Have a valid email address

0% INTEREST. 3 PAYMENTS. NO STRESS.

WHY PAY ANY OTHER WAY?

10 in stock

Or as low as R53.01 over 5 months interest free, using your credit card. For orders over R1.00.How it works
Categories: , SKU: 3MT7010-0AA10-0AP0 Brand:

Description

General technical data
size of contactor 0
product extension auxiliary switch Yes
power loss [W] for rated value of the current at AC in hot operating state 7.5 W
● per pole 2.5 W
insulation voltage
● of main circuit with degree of pollution 3 rated value 1 000 V
● of auxiliary circuit with degree of pollution 3 rated value 1 000 V
surge voltage resistance
● of main circuit rated value 6 kV
● of auxiliary circuit rated value 6 kV
protection class IP
● on the front IP20
mechanical service life (operating cycles)
● of contactor typical 10 000 000
reference code according to IEC 81346-2 Q
Substance Prohibitance (Date) 07/01/2022
Weight

Main circuit
number of poles for main current circuit 3
number of NO contacts for main contacts 3
operating voltage at AC-3 rated value maximum 690 V
operational current
● at AC-1 at 400 V at ambient temperature 40 °C rated value 25 A
● at AC-1 up to 690 V
— at ambient temperature 40 °C rated value 25 A
— at ambient temperature 60 °C rated value 19 A
● at AC-3
— at 400 V rated value 9 A
— at 690 V rated value 5.2 A
operating power
● at AC-3
— at 400 V rated value 4 kW
— at 690 V rated value 5.5 kW
no-load switching frequency
● at AC 1 800 1/h
operating frequency
● at AC-1 maximum 600 1/h
● at AC-3 maximum 750 1/h

Auxiliary circuit
number of NO contacts for auxiliary contacts
● instantaneous contact 1
operational current at AC-12 maximum 10 A
operational current at AC-15
● at 230 V rated value 6 A
● at 400 V rated value 3 A
● at 500 V rated value 2 A
● at 690 V rated value 1 A
operational current at DC-12
● at 24 V rated value 6 A
● at 110 V rated value 3 A
● at 220 V rated value 1 A
operational current at DC-13
● at 24 V rated value 6 A
● at 110 V rated value 1 A
● at 220 V rated value 0.3 A
● at 600 V rated value 0.1 A