TVS Contactor 32A 240V 15KW 1N/O AC3

R679.64

Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,32A,240V AC coil,50Hz,1NO auxiliary contact

Open Fact Sheet

Pay over 3 EQUAL zero-interest instalments of R226.55 with PayJustNow.
Find out how...

HOW IT WORKS

PayJustNow allows you to pay for your purchase over 3 payments with 0% interest and no fees. Pay a third at checkout and you get your goods as if you have paid in full. The remaining two instalments are debited on your specified instalment date.

Browse online or in-store and proceed to check-out

Choose PayJustNow as your payment method

Create your account and get an instant approval decision

Complete your transaction

WHAT YOU WILL NEED

BE OVER 18
YEARS OLD

BE AN SA
RESIDENT

HAVE A DEBIT OR
CREDIT CARD

HAVE A VALID
EMAIL ADDRESS

0% INTEREST. 3 PAYMENTS. NO STRESS.

WHY PAY ANY OTHER WAY?

16 in stock

Categories: , SKU: LC1E3210U5

Description

 

Main

Range Easy TeSys
Range of product Easy TeSys Control
Product or component type Contactor
Device short name LC1E
Contactor application Resistive load

Motor control

Utilisation category AC-3

AC-1

Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current 32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit

50 A (at <55 °C) at <= 440 V AC AC-1 for power circuit

[Uc] control circuit voltage 240 V AC 50 Hz

 

Complementary

Motor power kW 7.5 KW at 220…230 V AC 50/60 Hz (AC-3)

15 KW at 380…400 V AC 50/60 Hz (AC-3)

15 KW at 415 V AC 50/60 Hz (AC-3)

15 KW at 440 V AC 50/60 Hz (AC-3)

18.5 KW at 500 V AC 50/60 Hz (AC-3)

18.5 KW at 660…690 V AC 50/60 Hz (AC-3)

Pole contact composition 3 NO
[Ith] conventional free air thermal current 50 A (at 40 °C)
Irms rated making capacity 320 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity 256 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 260 A 40 °C – 10 s for power circuit

138 A 40 °C – 60 s for power circuit

60 A 40 °C – 600 s for power circuit

Associated fuse rating 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1

63 A gG at <= 690 V coordination type 1 for power circuit

Average impedance 2.5 MOhm – Ith 110 A 50 Hz for power circuit
Power dissipation per pole 2 W AC-3

5 W AC-1

[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 KV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability 8000000 Cycles
Electrical durability 1000000 Cycles AC-3

350000 Cycles AC-1

Control circuit type AC at 50 Hz
Control circuit voltage limits 0.85…1.1 Uc (-5…55 °C):operational 50 Hz

0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz

Inrush power in VA 95 VA 50 Hz cos phi 0.75 (at 20 °C)

95 VA 60 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA 8.3 VA 60 Hz cos phi 0.3 (at 20 °C)

8.5 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation 2…3 W for control circuit
Operating time 12…22 ms on closing

4…19 ms on opening

Maximum operating rate 1800 Cyc/H 60 °C
Connections – terminals Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end

Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end

Tightening torque Control circuit: 1.2 N.m

Power circuit: 2.1 N.m

Auxiliary contact composition 1 NO
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 MA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 Ms on energisation guaranteed between NC and NO contact

1.5 Ms on de-energisation guaranteed between NC and NO contact

Mounting support Plate

DIN rail

 

Environment

 

Standards IEC 60947-1

IEC 60947-5-1

IEC 60947-4-1

Product certifications ECA [RETURN]CE
IP degree of protection IP2X conforming to IEC 60529
Protective treatment TH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device -20…70 °C at Uc

-60…80 °C storage

-5…55 °C operation

Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Mechanical robustness Vibrations contactor open (1.5 Gn, 5…300 Hz)

Vibrations contactor closed (3 Gn, 5…300 Hz)

Shocks contactor closed (10 Gn for 11 ms)

Shocks contactor open (6 Gn for 11 ms)

Height 84 Mm
Width 56 Mm
Depth 86 Mm
Net weight 0.45 Kg

 

Packing Units

 

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.6 Cm
Package 1 Width 8.4 Cm
Package 1 Length 5.6 Cm
Package 1 Weight 449 Kg
Unit Type of Package 2 S02
Number of Units in Package 2 24
Package 2 Height 15 Cm
Package 2 Width 30 Cm
Package 2 Length 40 Cm
Package 2 Weight 11.184 Kg

 

Additional information

Weight 0.48 kg
Dimensions 7.4 × 4.5 × 8 cm