TVS Contactor 40A 415V 18.5KW 1N/O AC3

R1,010.93

FloatOr as low as R202.19 / month interest-free, using your existing credit card. For orders over R100.00.How it works

Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,40A,415V AC coil,50Hz

Open Fact Sheet

4 in stock

Categories: , SKU: LC1E40N5

Description

 

 

Main

Range Easy TeSys
Range of product Easy TeSys Control
Product or component type Contactor
Device short name LC1E
Contactor application Motor control Resistive load
Utilisation category AC-1 AC-3
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current 40 A (at <55 °C) at <= 440 V AC AC-3 for power circuit

60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

[Uc] control circuit voltage 415 V AC 50 Hz

 

Complementary

Motor power kW 18.5 KW at 380…400 V

11 KW at 220…230 V AC 50/60 Hz

22 KW at 415 V

22 KW at 440 V

22 KW at 500 V 30 KW at 660…690 V

Pole contact composition 3 NO
[Ith] conventional free air thermal current 60 A (at 55 °C)
Irms rated making capacity 400 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity 320 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 320 A 40 °C – 10 s for power circuit

165 A 40 °C – 60 s for power circuit

72 A 40 °C – 600 s for power circuit

Associated fuse rating 10 A gG at <= 690 V coordination type 1 for control circuit conformingto IEC 60947-5-1

80 A gG at <= 690 V coordination type 1 for power circuit

Average impedance 1.5 MOhm – Ith 60 A 50 Hz for power circuit
Power dissipation per pole 2.4 W AC-3 5.4 W AC-1
[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 KV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability 5000000 Cycles
Electrical durability 350000 Cycles AC-1 900000 Cycles AC-3
Control circuit type AC at 50 Hz
Control circuit voltage limits 0.85…1.1 Uc (-5…55 °C):operational 50 Hz 0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA 160 VA 50 Hz cos phi 0.75 (at 20 °C) 140 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 15 VA 50 Hz cos phi 0.3 (at 20 °C) 13 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 6…10 W for control circuit
Operating time 20…26 ms on closing 8…12 ms on opening
Maximum operating rate 1200 Cyc/H 55 °C
Connections – terminals Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible withcable end

Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexiblewith cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid withoutcable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid withoutcable end

Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexiblewith cable end

Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexiblewith cable end

Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: solid without cable end

Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: solid without cable end

Tightening torque Control circuit: 1.2 N.m Power circuit: 5 N.m
Auxiliary contact composition 1 NO + 1 NC
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 MA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 Ms on energisation guaranteed between NC and NO contact 1.5 Ms on de-energisation guaranteed between NC and NO contact
Mounting support Plate DIN rail

 

Environment

 

Standards IEC 60947-4-1 IEC 60947-1 IEC 60947-5-1
Product certifications EAC[RETURN]CE
IP degree of protection IP2X conforming to IEC 60529
Protective treatment TH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device -20…70 °C at Uc

-60…80 °C storage

-5…55 °C operation

Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Mechanical robustness Vibrations contactor open (1.5 Gn, 5…300 Hz)

Vibrations contactor closed (3 Gn, 5…300 Hz)

Shocks contactor open (6 Gn for 11 ms) Shocks

contactor closed (7 Gn for 11 ms)

Height 127 Mm
Width 75 Mm
Depth 114 Mm
Net weight 0.98 Kg

 

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.000 Cm
Package 1 Width 12.000 Cm
Package 1 Length 13.000 Cm
Package 1 Weight 976.000 G
Unit Type of Package 2 S02
Number of Units in Package 2 9
Package 2 Height 15.000 Cm
Package 2 Width 30.000 Cm
Package 2 Length 40.000 Cm
Package 2 Weight 9.031 Kg
Unit Type of Package 3 P06
Number of Units in Package 3 144
Package 3 Height 75.000 Cm
Package 3 Width 80.000 Cm
Package 3 Length 60.000 Cm
Package 3 Weight 152.496 Kg

 

Additional information

Weight 0.48 kg
Dimensions 7.4 × 4.5 × 8 cm