TVS Contactor 95A 415V 45KW 1N/O AC3

R1,514.38

Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,95A,415V AC coil,50Hz

Open Fact Sheet

Pay over 3 EQUAL zero-interest instalments of R504.80 with PayJustNow.
Or pay over 12 instalments of with PayJustNow.
Find out how...

Your flexible payment provider.

Example payment for

x 3
0% interest, zero fees.
Pay in 3
x 12
28% interest, plus fees.
Total Payment
Pay in 12

How does PayJustNow work?

You can complete sign-up in under 2 minutes - no need to leave your cart!

2 in stock

Or as low as R302.88 over 5 months interest free, using your credit card. For orders over R1.00.How it works
Category: SKU: LC1E95N5 Brand:

Description

 

Main

RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control

Resistive load

Utilisation categoryAC-1

AC-3

Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current95 A (at <55 °C) at <= 440 V AC AC-3 for power circuit

125 A (at <55 °C) at <= 440 V AC AC-1 for power circuit

[Uc] control circuit voltage415 V AC 50 Hz

 

Complementary

Motor power kW45 KW at 415 V

45 KW at 440 V

45 KW at 500 V

25 KW at 220…230 V AC 50/60 Hz

45 KW at 380…400 V

55 KW at 660…690 V

Pole contact composition3 NO
[Ith] conventional free air thermal current120 A (at 55 °C)
Irms rated making capacity950 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity760 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current135 A 40 °C – 600 s for power circuit

800 A 40 °C – 10 s for power circuit

400 A 40 °C – 60 s for power circuit

Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1

160 A gG at <= 690 V coordination type 1 for power circuit

Average impedance0.8 MOhm – Ith 110 A 50 Hz for power circuit
Power dissipation per pole7.2 W AC-3

12 W AC-1

[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 KV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability3000000 Cycles
Electrical durability900000 Cycles AC-1

350000 Cycles AC-3

Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85…1.1 Uc (-5…55 °C):operational 50 Hz

0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz

Inrush power in VA200 VA 50 Hz cos phi 0.75 (at 20 °C)

220 VA 60 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA22 VA 60 Hz cos phi 0.3 (at 20 °C)

20 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation6…10 W for control circuit
Operating time20…35 ms on closing

6…30 ms on opening

Maximum operating rate1200 Cyc/H 60 °C
Connections – terminalsControl circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without

cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end

Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end

Power circuit: screw clamp terminals 1 4…50 mm² – cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 2 4…16 mm² – cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 1 4…50 mm² – cable stiffness: solid without cable end

Power circuit: screw clamp terminals 2 4…50 mm² – cable stiffness: solid without cable end

Tightening torqueControl circuit: 1.2 N.m

Power circuit: 12 N.m

Auxiliary contact composition1 NO + 1 NC
Minimum switching voltage17 V for control circuit
Minimum switching current5 MA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 Ms on energisation guaranteed between NC and NO contact

1.5 Ms on de-energisation guaranteed between NC and NO contact

Mounting supportPlate

DIN rail

 

Environment

 

StandardsIEC 60947-5-1

IEC 60947-4-1

IEC 60947-1

Product certificationsEAC [RETURN]CE
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device-20…70 °C at Uc

-60…80 °C storage

-5…55 °C operation

Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5…300 Hz)

Vibrations contactor closed (3 Gn, 5…300 Hz)

Shocks contactor open (6 Gn for 11 ms)

Shocks contactor closed (7 Gn for 11 ms)

Height127 Mm
Width85 Mm
Depth121 Mm
Net weight1.52 Kg

 

Packing Units

 

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.800 Cm
Package 1 Width9.500 Cm
Package 1 Length13.500 Cm
Package 1 Weight1.520 Kg
Unit Type of Package 2S03
Number of Units in Package 25
Package 2 Height30.000 Cm
Package 2 Width30.000 Cm
Package 2 Length40.000 Cm
Package 2 Weight8.313 Kg

 