PTV 6 – Feed-through terminal block

 

Feed-through terminal block, nom. voltage: 1000 V, nominal current: 41 A, number of connections: 2, number of positions: 1, connection method: Push-in connection, Rated cross section: 6 mm2 , cross section: 0.5 mm2  – 10 mm2 , mounting type: NS 35/7,5, NS 35/15, color: gray

40 in stock

Categories: , SKU: 1116734

Description

Commercial Data Value
Item number 1116734
Packing unit 50 pc
Minimum order quantity 1 pc
Sales key BE2
Product key BE2311
GTIN 4063151043063
Weight per piece (including packing)

 

14.3 g
Weight per piece (excluding packing) 13.228 g
Customs tariff number 85369010
Country of origin CN

 

 

Product Properties Value
Product type Feed-through terminal block
Product family PTV
Area of application Railway industry
  Machine building
  Plant engineering
  Process industry
Number of positions 1
Number of connections 2
Number of rows 1
Insulation characteristics  
Overvoltage category III
Degree of pollution 3

 

 

ctrical Properties Value
Rated surge voltage 8 kV
Maximum power dissipation for nominal condition 1.31 W4o

 

 

Connection Data Value
Number of connections per level 2
Nominal cross section 6 mm²
Stripping length 10 mm … 12 mm
Internal cylindrical gage A5
Connection in accordance with standard IEC 60947-7-1
Conductor cross section rigid 0.5 mm² … 10 mm²
Cross section AWG 20 … 8 (converted according to IEC)
Conductor cross section flexible 0.5 mm² … 10 mm²
Conductor cross section, flexible [AWG] 20 … 8 (converted according to IEC)
Conductor cross section flexible (ferrule without plastic sleeve) 0.5 mm² … 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.5 mm² … 6 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² … 4 mm²
Nominal current 41 A
Maximum load current 52 A (with 10 mm² conductor cross section, rigid)
Nominal voltage 1000 V
Nominal cross section 6 mm²

 

 

Connection Cross Sections Directly Pluggable Value
Conductor cross section rigid 1.5 mm² … 10 mm²
Conductor cross section, rigid [AWG] 16 … 8 (converted according to IEC)
Conductor cross section flexible (ferrule without plastic sleeve) 4 mm² … 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 2.5 mm² … 6 mm²

 

Ex Data Value
Identification II 2 G Ex eb IIC Gb
Operating temperature range -60 °C … 110 °C
Ex-certified accessories4 1180894 D-PTV 6
3022276 CLIPFIX 35-5
1212602 SZS 0,6X3,5 VDE
List of  bridge Plug-in bridge / FBS 2-8 / 3030284
Plug-in bridge / FBS 3-8 / 3030297
Plug-in bridge / FBS 4-8 / 3030307
Plug-in bridge / FBS 5-8 / 3030310
Plug-in bridge / FBS 6-8 / 3032470
Plug-in bridge / FBS 10-8 / 3030323
Bridge data 36 A / 6 mm²
Ex temperature increase 40 K (35 A/6 mm²)
Rated voltage 550 V
For bridging with bridge 550 V
– At bridging between non-adjacent terminal blocks 352 V
– At bridging between non-adjacent terminal blocks via PE terminal block 352 V
– At cut-to-length bridging 220 V
– At cut-to-length bridging with cover 275 V
Rated insulation voltage 500 V
Output (Permanent)

 

Ex Level General Value
Rated current 35 A (6 mm²)
Maximum load current 45 A (10 mm²)
Contact resistance 0.5 mΩ

 

 

Ex Connection Data General Value
Nominal cross section 6 mm²
Rated cross section AWG 10
Connection capacity rigid 0.5 mm² … 10 mm²
Connection capacity AWG 20 … 8
Connection capacity flexible 0.5 mm² … 10 mm²
Connection capacity AWG 20 … 8

 

Dimensions Value
Width 8.2 mm
End cover width 2.2 mm
Height 61 mm
Depth 42.2 mm
Depth on NS 35/7,5 43.7 mm

 

Material Specifications Value
Color gray
Flammability rating according to UL 94 V0
Insulating material group I
Insulating material PA 6.6
Static insulating material application in cold -60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
Relative insulation material temperature index (Elec., UL 746 B) 125 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 – HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 – HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 – HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 – HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354) 27.5 MJ/kg
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Smoke gas toxicity NFPA 130 (SMP 800C) passed

 

Surge Voltage Test Value
Test voltage setpoint 8 kV
Result Test passed

 

emperature-rise Test Value
Requirement temperature-rise test Increase in temperature ≤ 45 K
Result Test passed
Short-time withstand current 6 mm² 0.72 kA
Result Test passed

 

Mechanical properties

Mechanical data

 

Open side panel Yes

Mechanical strength

 

Result Test passed

 

 

 

 

Attachment on the carrier

 

DIN rail/fixing support NS 35

 

 

Result Text passed

 

Mechanical Test: Rotation and Conductor Weight Value
Rotation speed 10 rpm
Revolutions 135
Conductor cross section/weight 0.5 mm²/0.3 kg
  6 mm²/1.4 kg
  10 mm²/2 kg
Result Test passed

 

 

Aging Test Value
Temperature cycles 192
Result Test passed

 

Oscillation/broadband noise Value
Specification DIN EN 50155 (VDE 0115-200):2018-05
Spectrum Service life test category 2, bogie-mounted
Frequency range f1 = 5 Hz to f2 = 250 Hz
ASD level 6.12 (m/s²)²/Hz
Acceleration 3.12g
Test duration per axis 5 h
Test directions X-, Y- and Z-axis
Result Test passed

 

 

 

 

 

 

 

 

 

 

Shock Test Value
Specification DIN EN 50155 (VDE 0115-200):2018-05
Pulse shape Half-sine
Acceleration 30g
Shock duration 18 ms
Number of shocks per direction 3
Test directions X-, Y- and Z-axis (pos. and neg.)
Result Test passed

 

 

 

Ambient Conditions Value
Ambient temperature (operation) -60 °C … 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport) -25 °C … 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly) -5 °C … 70 °C
Ambient temperature (actuation) -5 °C … 70 °C
Permissible humidity (operation) 20 % … 90 %

 

 

 

Permissible Humidity (Storage/Transport) Value
Permissible humidity (storage/transport) 30 % … 70 %

 

 

 

 

 

Standards and regulations

 

Connection in acc. with standard IEC 60947-7-1

 

Mounting

 

Mounting type NS 35/15

 

Classifications

 

ECLASS-11.0 27141120
ECLASS-13.0 27250101

 

ETIM

 

ETIM 9.0 EC000897

 

UNSPSC

 

 

UNSPSC 21.0 39121400

 

Environmental product compliance

EU RoHS

 

Fulfills EU RoHS substance requirements Yes, No exemptions

China RoHS

 

Environment friendly use period (EFUP) EFUP-E No hazardous substances above the limits

 

EU REACH SVHC

 

REACH candidate substance (CAS No.) No substance above 0.1 wt%

Additional information

Weight 0.322 kg
Dimensions 4.57 × 0.75 × 0.52 cm