TELE LIMIT SWITCH BODY ZCD 2 NC & 1 NO

R953.24

Limit switch body, Limit switches XC Standard, ZCD, compact, 2NC+1 NO, snap action

Pay in 3 or 12. The Clever Way to Pay.
From over 12 months or 3 interest free payments.
Learn more...

Your flexible payment provider.

Example payment for

x 3
0% interest, zero fees.
Pay in 3
x 12
28.25% interest, plus fees.
Total Payment
Pay in 12

How does PayJustNow work?

  • Shop and choose PayJustNow at checkout.
  • Sign up and get instant approval.
  • Pay in 3 or 12.

You can complete sign-up in under 2 minutes - no need to leave your cart!

20 in stock

Or as low as R190.65 over 5 months interest free, using your credit card. For orders over R1.00.How it works

Description

Main
Range of product Telemecanique Limit switches XC Standard
Series name Standard compact
Product or component
type

Limit switch body
Device short name ZCD
Design Compact
Body type Fixed
Associated head ZCE28
ZCEH0
ZCE10
ZCE08
ZCE07
ZCE67
ZCE64
ZCEH2
ZCE27
ZCE01
ZCE65
ZCE02
ZCE05
ZCE14
ZCE11
ZCE29
ZCE63
ZCE21
ZCE09
ZCE24
ZCE13
ZCE66
ZCE06
ZCE62
Body material Zamak
Number of poles 3
Contacts type and
composition

2 NC + 1 NO
Contact operation Snap action

Complementary
Associated connection component ZCDEP16
ZCDEP20
ZCDEG11
ZCDEG13
ZCDEF12
ZCDEN12

Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 0.75 mm2
Contacts insulation form Zb
Contacts material Silver plated contacts
Positive opening With
Minimum actuation speed 0.01 m/s
Contact code designation R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
C300, AC-15 (Ue = 240 V), Ie = 0.75 A conforming to IEC 60947-5-1 appendix A

[Ui] rated insulation voltage 300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
400 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage 4 KV conforming to IEC 60664
4 kV conforming to IEC 60947-1
Short-circuit protection 6 A cartridge fuse, type gG

Electrical durability 5000000 Cycles, DC-13 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5

conforming to IEC 60947-5-1 appendix C
5000000 Cycles, DC-13 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5
conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5
conforming to IEC 60947-5-1 appendix C

Width 31 mm
Height 65 mm
Depth 30 mm

Environment
Product compatibility XCKD
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…70 °C